Controller functions
RES-445
Page 31
25
Set point exceeded
(high limit)
If the actual value is less than the switching
threshold specified here and greater than the
threshold set with step 24, the "Temperature OK"
output is activated.
The value is entered in Kelvins (K) and added to the
set point in order to calculate the switching
threshold.
+5K…+99K
26
Time control
This menu step specifies whether the controller
should operate with or without time control.
ON,
ON with START
monitoring,
OFF
27
Cooling mode
The end of the cooling-down phase (end of cycle)
can be configured by specifying the required
cooling mode.
• Absolute: The cycle ends if the actual value falls
below the cooling temperature set here.
Absolute (in °C)
• Relative: The cycle ends if the actual value falls
below the relative cooling temperature
(percentage of the set point) set here.
Relative (in %)
• Time: The cycle ends when the set cooling time
has elapsed.
This function can only be selected if time control
(step 26) is active.
Time (in s)
28
Start of heatsealing
time
This menu step specifies whether the heatsealing
time (step 4) should begin as soon as the start
signal is applied or when 95% of the set point is
reached.
This function can only be selected if time control
(step 26) is active.
Heatsealing time starts
when heating starts
Heatsealing time starts
when temperature
reached
No.
Name
Description
Setting range