Controller functions
Page 30
RES-445
20
Language
The desired display language can be selected with
this menu step.
English
German
Italian
SW revision 015 or higher
also:
French, Spanish, Dutch,
Danish, Finnish, Swedish,
Greek, Turkish.
SW revision 024 or higher
also: Portuguese.
21
Factory settings
The controller can be reset to the factory settings by
pressing the "ENTER" key. The default values are
loaded in the controller again (
!
22
Alloy/range
Various heatsealing band alloys and temperature
ranges can be selected here.
The corresponding characteristic for the controller
parameters is calculated on the basis of this setting.
Please be very careful to select the
heatsealing band material with the correct
alloy.
The temperature range setting permits the
controller to be matched to the required operating
range. This also determines the scale for the bar
display and the analog output.
(Availability depends on
SW revision)
TCR 410ppm, 300°C
TCR 460ppm, 300°C
TCR 510ppm, 300°C
TCR 570ppm, 300°C
TCR 630ppm, 300°C
TCR 700ppm, 300°C
TCR 780ppm, 200°C
TCR 780ppm, 300°C
TCR 780ppm, 400°C
TCR 780ppm, 500°C
TCR 870ppm, 300°C
TCR 980ppm, 300°C
TCR 1100ppm, 200°C
TCR 1100ppm, 300°C
TCR 1100ppm, 400°C
TCR 1100ppm, 500°C
TCR 3500ppm, 200°C
TCR 3500ppm, 300°C
23
Maximum
temperature
This menu item specifies the maximum selectable
set point (step 1) and the maximum selectable
preheating temperature (step 2) within the range
defined by step 22.
0 to max. temperature
range (step 22)
24
Set point reached
(low limit)
If the actual value is greater than the switching
threshold specified here and less than the threshold
set with step 25, the "Temperature OK" output is
activated.
The value is entered in Kelvins (K) and subtracted
from the set point in order to calculate the switching
threshold.
-5K…-99K
No.
Name
Description
Setting range
!