Programmable Thermostat

Installation Manual

Wiring

Battery power or 24V hardwire

Operate on 1 stage heat and 1 stage cool

Low battery indicator

10. Caution

11. Specifications

The display range of temperature ..............................................................  41°F to 95°F

5°C to 35°C

The control range of temperature .............................................................  44°F to 90°F 

7°C to 32°C

Load rating .......................................... 1 amp per terminal, 1.5 amps maximum all terminals combined
Display accuracy ........................................................................................................................ ± 0.5°C
Power source ................................ 18 to 30 VAC, NEC Class II, 50/60 Hz for hardwire (common wire)
                                                                                              Battery power from 2 AAA alkaline betteries
Operating ambient ................................................................................ 41°F to +95°F 

5°C to +35°C

Operating humidity .............................................................................. 90% non-condensing maximum
Dimensions of thermostat ......................................................................................... 4.64”×3.46”×1.18”
                                                                                                                               1 1.8cm×8.8cm×3cm 

Thermostat Base

5+2 programmable

Heat pump without aux or emergency heat

Gas, electric or oil
Optional temperature display of fahrnheit or

celsius scale.

1. When the temperature is outside the display range the words HI or LO will be shown on the display 

    instead of a number. If the temperature higher than the display range, it will read HI. If the temperature

    lower than the display range, it will read LO. 
2. Two AAA batteries thermostat operates on last up to 1 year. The battery voltage symbol will flash to 

    indicate when batteries need replacement. When the battery voltage symbol flashes change batteries

    as soon as possible.
3. When changing batteries replace batteries within 20 minutes of removing the old ones to maintain 

    programmed settings such as time and date.
4. The thermostat is shipped with a protective film on the LCD screen. To remove the film, pull away from

    the corner.
5. Do Not use excessive force when attaching the thermostat to the wall bracket. Ensure all pins are 

    aligned correctly and firmly push the thermostat into position.
6. The thermostat contains precision electronics. Handle with care. Do not expose to dirt or moisture.

Thank you for choosing the CPT11 Thermostat. 

This thermostat has many features that can help 

you control your climate control systems. Please 

read this manual carefully before installation to 

ensure proper function and that you take advantage 

of the many features of this programmable thermostat.

Thermostat & Battery Installation

2. Production Functions Overview

2.1 Applications

A trained, experienced 

technician is recommended

for installation.

Please read instructions carefully. 

Failure to follow instructions 

completely may result in injury or 

damage.

2.2 Features

Summary of Contents for CPT11

Page 1: ...s thermostat operates on last up to 1 year The battery voltage symbol will flash to indicate when batteries need replacement When the battery voltage symbol flashes change batteries as soon as possible 3 When changing batteries replace batteries within 20 minutes of removing the old ones to maintain programmed settings such as time and date 4 The thermostat is shipped with a protective film on the...

Page 2: ...hange Filter symbol is displayed the number of the days set for filter change interval time has elapsed TENZA Up button In heating cooling mode the Up button raises the temperature setting When programming the Up button will also be used for changing system parameters Down button In heating cooling mode the Down button lowers the temperature setting When programming the Down button will be used fo...

Page 3: ...Close to hot or cold air ducts In direct sunlight On an outside wall In a corner or behind a door Where there are concealed chimneys or pipes in the wall behind Select an appropriate location The temperature of the location should be representative of the building Insert a screwdriver into the slot and pry up the front part of the panel to open it For horizontal mount put one screw left in the lef...

Page 4: ...ted to the G terminal 2 Loosen the terminal block screws insert wires then retighten terminal block screws 3 Place nonflammable insulation into wall opening to prevent drafts Use shielded or non shielded 18 22 gauge thermostat wire Do Not over tifhten terminal block screws as this can damage terminal block Keep the correctly fitted to the base to avoid operation issues Heat pump changeover value e...

Page 5: ...setting interface and the changed parameters will not be saved When the power is on in cool heat mode hold SET for 5 seconds to enter the programming mode LUVW VHW WKH V VWHP FORFN ZKHQ WKH FORFN DUHD LV IODVKLQJ SUHVV ȁ RU 9 WR FKDQJH WKH FORFN QG LI RX KROG ȁ RU 9 WKH DGMXVPHQW ZLOO EH DFFHOHUDWHG 3UHVV 6 7 DJDLQ WR VHW WKH ZHHN ZKHQ WKH ZHHN LV IODVKLQJ SUHVV ȁ RU 9 WR FKDQJH the day of the wee...

Page 6: ... at 30 right to the snaps Step 3 Press the lower part front of the display panel to complete the installation 6 Select filter change counter Select F8 0 the backlight will turn off in 5 seconds Select F8 1 backlight will be always on With the power off hold F button for 5 seconds Symbol dE will be displayed in thr temperature area then press RUN key to confirm and exit High quality alkaline batter...