(1) SYSTEM switch: Use this switch to select system mode: COOL->OFF->HEAT.

(2) FAN switch: Use this switch to select fan mode: AUTO->ON.

(3) FAN operation switch: Use this switch to select to options for heat fan: 

using a Gas or Oil heating system, choose “GAS” (system controls fan operation).

(4) Setting temperature: In the main interface, the LCD displays room temperature. When power is on, 

SUHVV³ȁ´RU³9´WRVHWWKHWHPSHUDWXUH7KH/&'ZLOOVKRZWKHVHWWHPSHUDWXUH3UHVV³9´WRORZHUWKH

VHWWLQJWHPSHUDWXUHDQGSUHVV³ȁ´WRUDLVHWKHVHWWLQJWHPSHUDWXUH,IWKHUHDUHQRRSHUDWLRQVRU

adjustments made within 5 seconds, the system will revert back to the main interface.

(5) Hold button: When power is on, press the “Hold” button to hold the setting temperature. The program 
will not run and display “Hold”. For example: if the set temperature is 60°F , after pressing the “HOLD”, 
the system will lock the setting temperature to be 60°F.
(6) Run button: When power is on, the button is used to run the program what has been set.
(7) F button: When power is on, and the filter function has been set (F6>0), pressing the F button will 
display the remaining time until the filter should be changed. For example: the clock area displays 128, 
which means it has 128 days left before filter net needs to be changed. Press and hold F button for 5 
seconds, “FILTER” icon will flash once, which means the filter will clear to zero and it will restart. 

(If there are no inputs for 30 seconds, the system will automatically exit the setting interface and the 

changed parameters will not be saved.)

When the power is on (in cool/heat mode), hold “SET” for 5 seconds to enter the programming mode:

)LUVWVHWWKHV\VWHPFORFNZKHQWKHFORFNDUHDLVIODVKLQJSUHVV³ȁ´RU³9´WRFKDQJH

WKHFORFN$QGLI\RXKROG³ȁ´RU³9´WKHDGMXVPHQWZLOOEHDFFHOHUDWHG

3UHVV³6(7´DJDLQWRVHWWKHZHHNZKHQWKHZHHNLVIODVKLQJSUHVV³ȁ´RU³9´WRFKDQJH

the day of the week.

(3) Press “SET” again to set the wake time from monday to friday. When the clock area is flashing,

SUHVV³ȁ´RU³9´WRDGMXVWWKHWLPH

(4) Press “SET” again to set the wake temperature from monday to friday. When the temperature

DUHDLVIODVKLQJSUHVV³ȁ´RU³9´WRDGMXVWWKHWHPSHUDWXUH

(5) Continue pressing “SET” to set the time and temperature of  leave, return, sleep, from monday to 

friday and saturday, sunday by in this order.

(6) After finished setting, press “RUN” to cancel the interface and save the parameter changes.

With power off, hold the set button for 7 seconds to enter the parameter changing interface.

System clock area displays each symbol of the parameter, and temperature area displays each 

of the parameter values. Continue to press “SET” to cycle the display through each parameter.

3UHVV³ȁ´RU³9´WRDGMXVWHDFKSDUDPHWHU$IWHU\RXKDYHILQLVKHGFKDQJLQJWKHSDUDPHWHUV

press “RUN” button to exit the setting interface and save the set parameter. (If there are no inputs 

within 30 seconds, the system will exit the setting interface and the changed parameters will not 

be saved)

21°C/69.8°F

21°C/69.8°F

17°C/62.6°F

17°C/62.6°F

24°C/75.2°F

24°C/75.2°F

28°C/82.4°F

26°C/78.8°F

21°C/69.8°F

21°C/69.8°F

17°C/62.6°F

17°C/62.6°F

24°C/75.2°F

24°C/75.2°F

28°C/82.4°F

26°C/78.8°F

Summary of Contents for CPT11

Page 1: ...s thermostat operates on last up to 1 year The battery voltage symbol will flash to indicate when batteries need replacement When the battery voltage symbol flashes change batteries as soon as possible 3 When changing batteries replace batteries within 20 minutes of removing the old ones to maintain programmed settings such as time and date 4 The thermostat is shipped with a protective film on the...

Page 2: ...hange Filter symbol is displayed the number of the days set for filter change interval time has elapsed TENZA Up button In heating cooling mode the Up button raises the temperature setting When programming the Up button will also be used for changing system parameters Down button In heating cooling mode the Down button lowers the temperature setting When programming the Down button will be used fo...

Page 3: ...Close to hot or cold air ducts In direct sunlight On an outside wall In a corner or behind a door Where there are concealed chimneys or pipes in the wall behind Select an appropriate location The temperature of the location should be representative of the building Insert a screwdriver into the slot and pry up the front part of the panel to open it For horizontal mount put one screw left in the lef...

Page 4: ...ted to the G terminal 2 Loosen the terminal block screws insert wires then retighten terminal block screws 3 Place nonflammable insulation into wall opening to prevent drafts Use shielded or non shielded 18 22 gauge thermostat wire Do Not over tifhten terminal block screws as this can damage terminal block Keep the correctly fitted to the base to avoid operation issues Heat pump changeover value e...

Page 5: ...setting interface and the changed parameters will not be saved When the power is on in cool heat mode hold SET for 5 seconds to enter the programming mode LUVW VHW WKH V VWHP FORFN ZKHQ WKH FORFN DUHD LV IODVKLQJ SUHVV ȁ RU 9 WR FKDQJH WKH FORFN QG LI RX KROG ȁ RU 9 WKH DGMXVPHQW ZLOO EH DFFHOHUDWHG 3UHVV 6 7 DJDLQ WR VHW WKH ZHHN ZKHQ WKH ZHHN LV IODVKLQJ SUHVV ȁ RU 9 WR FKDQJH the day of the wee...

Page 6: ... at 30 right to the snaps Step 3 Press the lower part front of the display panel to complete the installation 6 Select filter change counter Select F8 0 the backlight will turn off in 5 seconds Select F8 1 backlight will be always on With the power off hold F button for 5 seconds Symbol dE will be displayed in thr temperature area then press RUN key to confirm and exit High quality alkaline batter...

Reviews: