Device functions
Page 33
UPT-6011
Version 5
4
1
SINT
Calibration temperature
20 °C
-1 (= variable),
0…40 °C
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 04 30 01
4
WORD
Descriptor
0x0000
5
USINT
Data type
0xC2
6
USINT
Data length
1
5
1
UINT
Heating time limit (10 ms steps)
500
(5.00 s)
0…999
(0…9.99 s)
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 05 30 01
4
WORD
Descriptor
0x0004 (scaling supported)
5
USINT
Data type
0xC7
6
USINT
Data length
2
13
USINT
Factor
1
14
USINT
Divisor
100
15
USINT
Base
1
16
USINT
Offset
0
6
1
USINT
Measuring impulse duration
1.7 ms
(17)
1.7…3.0 ms
(17…30)
2
USINT
Link path length
6
3
EPATH
Link path
20 0F 24 06 30 01
4
WORD
Descriptor
0x0004 (scaling supported)
5
USINT
Data type
0xC6
6
USINT
Data length
1
13
USINT
Factor
1
14
USINT
Divisor
10
15
USINT
Base
1
16
USINT
Offset
0
Instanc
e
Attri-
bute
ID
Data
type
1
Name
Default
value
Value range