Mounting and installation
Version 5
UPT-6011
Page 10
The compact design of the CIRUS
®
Temperature Controller UPT-6011 as well as the plug-in connecting terminals
make mounting and installation easier.
An overview of the most important features and functions:
• Easy calibration of the heating element through AUTOCAL, the automatic zero-point setting
• Eight channels permit switching of the calibration parameters during tool change.
• High flexibility: The AUTORANGE function covers a secondary voltage range of 0.4 V to 120 V and a current
range of 30 A to 500 A.
• Automatic adjustment to the network frequency in the range of 47 Hz to 63 Hz
• Wide voltage range for flexible use from 110 VAC to 480 VAC
1
(as from 02/2021)
• Easy and convenient system diagnosis and process visualisation through the free, downloadable software
ROPEXvisual
®
• Comprehensive error diagnosis over the EtherNet/IP
TM
interface
• Booster output available for connecting a switching amplifier
• High process security through comprehensive options for evaluating the parameter data (e.g. temperature
diagnosis or heat-up time monitoring)
6
Mounting and installation
See also section 2 "General information" on page 3.
Mounting, installation and startup may only be performed by authorized persons who have received
suitable instruction and are familiar with the associated risks and warranty provisions.
The supply voltage to the machine side must lie within the permitted voltage and frequency range
of the CIRUS
®
Temperature Controller. Otherwise, there is the danger of a defect.
6.1
Installation notes
1. Please refer to the safety and warning notes (
“General information” on page 3.).
2. The information provided in the customized ROPEX Application Report, which is specifically prepared by
ROPEX for each application, must be observed.
3. All electrical components such as the controller, impulse transformer, and line filter, should be installed as close
as possible to the UPT sealing bar(s) in order to avoid unnecessarily long cables.
4. Connect the voltage measurement cable UR directly to the UPT sealing bar and lay it twisted to the controller
(for the UML-1 voltage measurement cable see
5. Ensure an adequate cable cross-section for the primary and secondary circuits (Ä Application Report).
6. Use only ROPEX impulse transformers or transformers approved by ROPEX. Please note the power, duty
cycle, and primary and secondary voltages (Ä Application Report).
6.2
Installation procedure
Proceed as follows to install the CIRUS
®
Temperature Controller UPT-6011:
1. Switch off the line voltage and the 24 VDC supply, and verify that the circuit is de-energized.
1. Standard: 415 VAC, optional and on request: 480 VAC
!
!