background image

RONK Automatic Transfer Switch Owner’s Manual 

29

WARRANTY

AUTOMATIC TRANSFER SWITCH
OWNER WARRANTY POLICY

LIMITED WARRANTY

RONK Electrical Industries, Inc. will repair or replace, free 
of charge, any part(s) of the equipment that is defective in 
material or workmanship or both providing that installation 
of the equipment complies with all applicable codes, industry 
standards, laws, regulations and provided installation manual. 
RONK’s ATS and associated components shall be installed only 
by a licensed electrical contractor, and otherwise this warranty 
is void. This warranty is effective for the time period and subject 
to the conditions stated below. For warranty service, please call 
RONK Electrical Industries, Inc. at 1-217-563-8333.

THERE ARE NO OTHER EXPRESS WARRANTIES OR IMPLIED 
WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE. THE ABOVE WARRANTY IS 
LIMITED TO TWO YEARS FROM PURCHASE. ANY AND ALL IMPLIED 
WARRANTIES ARE EXCLUDED AND LIABILITY FOR INCIDENTAL 
OR CONSEQUENTIAL DAMAGES ARE EXCLUDED TO THE EXTENT 
EXCLUSION IS PERMITTED BY LAW. BUYER’S SOLE REMEDY IS THE 
LIMITED WARRANTY STATED ABOVE.

This warranty only applies to units sold for use in the United 
States of America and Canada.

WARRANTY PERIOD

Consumer Use: 2 years 
Commercial Use: 2 years

The warranty period begins on the date of purchase by the first 
retail consumer and continues for the period stated above. 
Equipment used for primary power in place of utility is not 
applicable to this warranty.

WARRANTY REGISTRATION PROCESS

Thank you for choosing RONK’s Automatic Transfer Switch for 
your generator system!

1. For the fastest and most efficient way to register your ATS 

warranty, please complete the online form at ronkelectrical.
com/warranty (preferred method). Otherwise, please complete 
the postcard and return via mail.

2. Complete the online form or return the postcard within 10 

days of installation.

3. Save the proof of purchase. If your switch is not registered 

within 10 days, the warranty start date will default to the date 
of purchase by the first retail consumer.

4. If the warranty registration steps are not completed, the 

warranty start date will default to the manufacturing date.

ABOUT OUR WARRANTY

Warranty repairs are handled routinely, but sometimes requests 
for warranty service may not be appropriate or applicable. For 
example, warranty service would not apply if equipment damage 
occurred because of misuse, lack of routine maintenance, 
shipping, handling, warehousing, or improper installation.

Similarly, the warranty is void if the manufacturing date or the 
serial number on the equipment has been removed, altered, 
or modified. During the warranty period defined above, the 
authorized certified technician, at its option, will repair or replace 
any part that, upon examination, is found to be defective under 
normal use and service. No allowances shall be made to the 
Buyer for any transportation, duties, brokerage fees, labor costs, 
or parts adjustments or repairs, or any other work, unless said 
charges have been authorized in writing, in advance, by the 
Seller. The Seller shall not be liable for determining whether 
any Article(s) or parts thereof are suitable for the Buyer’s or any 
third-party’s intended use or application. The Seller shall in no 
event be liable for any special or consequential damages or for 
loss of profit as a result of a breach of this warranty, including 
without limitation, any damages relating to any direct or 
indirect damage to property resulting from any use, removal or 
installation of the article(s) by the Buyer or any third-party.

This warranty will not cover the following repairs and equipment:

• Normal Wear: Electrical equipment, like any mechanical device, 

needs periodic parts and service to perform well. This warranty 
does not cover repair when normal use has exhausted the life 
of the part or equipment.

• Installation and Maintenance: This warranty does not apply to 

equipment or parts that have been subjected to improper or 
unauthorized installation or alteration or modification, misuse, 
negligence, accident, overloading, improper maintenance, 
repair or storage so as, in our judgment, to adversely affect its 
performance and reliability. This warranty also does not cover 
normal maintenance such as adjustments, cleaning and fuse 
replacement.

Other exclusions: This warranty excludes wear items or damage 
or malfunctions resulting from accidents, abuse, modifications, 
alterations, or improper servicing. Accessory parts are excluded 
from the product warranty. This warranty excludes failure due 
to acts of God and other force majeure events beyond the 
manufacturer’s control. Also excluded is used, reconditioned, 
and demonstration equipment. The warranty shall not apply 
to any materials or parts thereof furnished by the Buyer, or 
acquired from others at the Buyer’s request and/or the Buyer’s 
specifications or designs.

Summary of Contents for 100-600 AMP

Page 1: ...OWNER S INSTALLATION MANUAL 100 600 AMP RONK Automatic Transfer Switch...

Page 2: ...plain and or exemplify a product service or maintenance improvement We reserve the right to make any change at any time without notice Some images may vary depending upon which model is shown ALL RIGH...

Page 3: ...e 8 SPECIFICATIONS 9 RONK ATS 100A 200A 400A 600A Specifications 9 INSTALLATION AND WIRING 10 General Information 10 Mounting Location 10 Mounting Requirements 10 Recommended Upstream Protection 11 Po...

Page 4: ...anual Transfer 21 400A Manual Transfer 21 600A Manual Transfer 22 MAINTENANCE 23 Recommended Maintenance 23 Maintenance 23 DRAWINGS 24 100A 200A 240V Schematic 24 400A 240V Schematic 25 400A 480V Sche...

Page 5: ...efore use Refer to the installation section of this manual for instructions on installation procedures Only licensed electrical contractors should install an ATS Installations must comply completely w...

Page 6: ...ion in the manner intended The manufacturer of this product cannot reasonably anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals aff...

Page 7: ...ocution Do not touch bare wires Do not use equipment with worn frayed bare or otherwise damaged wiring Do not handle electrical cords while standing in water while barefoot or while hands or feet are...

Page 8: ...the enclosure Care should be taken to always protect the equipment from impact Do not remove the protective packaging until the equipment is at the installation site and ready to be installed A shipp...

Page 9: ...x 6 ATS40012 W04 1 400 240 181 lbs 48 x 30 x 10 ATS40014 W04 1 400 480 203 lbs 48 x 30 x 10 ATS40032 W04 3 400 240 188 lbs 48 x 30 x 10 ATS40034 W04 3 400 480 210 lbs 48 x 30 x 10 ATS60012 N06 1 600...

Page 10: ...er FDC 150 A Eaton Cutler Hammer QCHW 125 A Eaton Cutler Hammer FCL 100 A Eaton Cutler Hammer FB 100 A SQUARED D FI 100 A V22 1 200 240 10 kA 0 025 Seconds 22 kA Siemens FXD 250 A Siemens NFK 250 A SQ...

Page 11: ...an the circuit breakers with the recommended ratings given above may cause improper operation of the switch WARNING Low voltage wire cannot be installed in the same conduit as power voltage wiring It...

Page 12: ...he remote start stop connections of the generator to allow automatic starting These are N O dry contacts 8A 35 Vdc Max An optional customer supplied test switch may be installed by the customer using...

Page 13: ...s automatic start controller When the ATS controller senses that the generator has started and is within acceptable limits the transfer switch will wait until the utility to generator time delay Para...

Page 14: ...me and day when the battery is re applied SCHEDULER The DSE331 scheduler is the feature that sets the exercise timer for the Automatic Transfer Switch and the generator set The ATS comes from the fact...

Page 15: ...e 240V switches are usable on 208V systems See manual for instructions to change parameters TIME DELAY FUNCTION SETTING LINE Transient 2 Seconds Engine Start 13 Seconds Transfer LINE to AUXILIARY 21 S...

Page 16: ...provides a quick start guide to the module s operation for DSE controller 331 MODE SELECTION OPERATION NOTE For further details see the section entitled MODE SELECTION elsewhere in this manual Press...

Page 17: ...LCD display until the user selects a different page or after an extended period of inactivity the module will revert to the status display When scrolling manually the display will automatically return...

Page 18: ...ch Owner s Manual QUICKSTART GUIDE INSTRUMENTATION The instrumentation page contains the following information S1 Voltage L N S1 Voltage L L S1 Frequency S2 Voltage L N S2 Voltage L L S2 Frequency Bat...

Page 19: ...Switch Fail Alarm The Switching device has failed to operate Failed to Start The engine has not fired after the preset number of start attempts Failed to Stop The module has detected a condition that...

Page 20: ...mode is used to provide an over ride function to prevent the controller from starting the generator in the event of a remote start S1 out of limits condition occurring Prohibit return This mode is use...

Page 21: ...ovable lever handle is used to transfer the mechanism The transfer switch is in the utility position when reference A on the contactor is set to the ON position and reference B is set to the OFF posit...

Page 22: ...h Trip using an object such as a screwdriver to open the utility poles 2 Set the removable handle on M and operate in the UP direction while pushing select with the screwdriver To transfer from Genera...

Page 23: ...ation for possible safety hazards Inspect mounting location for any safety or fire hazards Inspect for dirt wiring damage and mechanical damage Inspect the transfer switch for loose hardware Check all...

Page 24: ...24 RONK Automatic Transfer Switch Owner s Manual WIRE DIAGRAM DRAWINGS 100A AND 200A SCHEMATIC Source 1 LINE Utility Source 2 AUXILIARY Generator...

Page 25: ...RONK Automatic Transfer Switch Owner s Manual 25 WIRE DIAGRAM DRAWINGS 400A 240V SCHEMATIC Source 1 LINE Utility Source 2 AUXILIARY Generator...

Page 26: ...26 RONK Automatic Transfer Switch Owner s Manual WIRE DIAGRAM DRAWINGS 400A 480V SCHEMATIC Source 1 LINE Utility Source 2 AUXILIARY Generator...

Page 27: ...RONK Automatic Transfer Switch Owner s Manual 27 WIRE DIAGRAM DRAWINGS 600A 240V SCHEMATIC Source 1 LINE Utility Source 2 AUXILIARY Generator...

Page 28: ...28 RONK Automatic Transfer Switch Owner s Manual WIRE DIAGRAM DRAWINGS 600A 480V SCHEMATIC Source 1 LINE Utility Source 2 AUXILIARY Generator...

Page 29: ...licable For example warranty service would not apply if equipment damage occurred because of misuse lack of routine maintenance shipping handling warehousing or improper installation Similarly the war...

Page 30: ...30 RONK Automatic Transfer Switch Owner s Manual NOTES...

Page 31: ...RONK Automatic Transfer Switch Owner s Manual 31...

Page 32: ...106 E State Street Nokomis IL 62075 800 221 7665 www ronkelectrical com...

Reviews: