35
Safety functions
Temperature sensor control
If the temperature sensor measures an abnormal value (tolerable temperature range: -10 °C - 260 °C), the
display will show an error code.
Temperature control
This function will be active, if the temperature sensor of the respective grilling area does not measure an
increase of at least 10 °C within 3 minutes after setting a higher temperature level.
Safety switch-off
The safety switch-off will be active, if one or more buttons are applied permanently for more than 20
seconds. The function cuts the power supply. The temperature indication shows an error code.
Operating time limitation
The operating time limitation will switch the appliance automatically off if no button has been applied for
a period of two hours. The operating time limitation works independently of the set temperature. After an
automatic switch-off, the appliance can be put into operation and the max. operating time will be active
again.
Cooling system
The control unit has a fan for cooling the electronics. The fan switches on and off dependent on the tem-
perature inside the control unit. If a temperature >85 °C inside the control unit is measured, the power
supply will be cut and there will be an error code in the temperature indication.
Safety switch
The control unit has a safety switch on the rear side. The switch is activated by a contact pin positioned on
the base. The switch ensures that the appliance can only be operated if assembled correctly.
• Do not use a scouring agent or dissolvent!
• Do not use oven sprays for cleaning!
• Never use a steam jet appliance for cleaning the base and the grill plate!
NOTE:
Prior to the next use, the grill plate and the electrical connection must be completely dry.