Step 6 - Sealing
1. Seal the base of the enclosure to the top of the tray from wall to wall on the outside only making sure
that you seal around the Dam and Joiner as shown. Seal the Dam vertically where it meets the Vertical
Frame.
• IMPORTANT: Failure to carry out stage 1 may result in serious water damage and is not covered under
the terms of the guarantee.
• DO NOT seal the base of the product to the inside, failure to comply may result in the product leaking.
• Allow 24 hours for the sealant to fully cure prior to using the shower.
2.
Fit the Bottom Seal onto the bottom of the glass making sure it fits between the Pivot Tube and the Door
Magnet (trim to length if required). Ensure that the deflector is facing inward towards the shower.
• Make sure the Magnets on the door and frame locate onto each other down the full length of the door.
• If the Seal drags over the Bottom Rail, the door may need raising at the magnet side. Unscrew the top
3-4 door fixing screws, raise the door, re-drill and re-fix.
3. Remove the release paper from the Adhesive Tape supplied and place the Tape on the face of the Vertical
Door Frame, ensuring the Tape is positioned to one side of the screw heads.
• The longer Cover Strip is for the pivot side of the product.
4.
Place one side of the Cover Strip over the leg on the Vertical Frame and press firmly to stick the Cover Strip
to the Frame.
5. The Top Caps have grooves and can be shortened by cutting along these grooves using scissors or snips
(adding a small amount of sealant will help keep the caps in place).
6. Place the Branding Badge in a prominent position on a none moving part of aluminium.
①
Cut off
here
Cut off
here
①
Grooves
⑤
②
Deflector to
face inward
towards the
shower
③④
Cover Strip
Adhesive Tape