24
Display menu
Explanation
Remarks
Factory default
•
Submenu
Choosing this moves to the submenu.
—
—
SuperFine
Set this to ON when using a 0.13 mm or 0.18 mm [*SuperFine] is displayed when this has been
OFF
♦
ink pen.
selected.
Top
Choosing this returns to the top menu.
—
—
VectorSort
When ON is setting, this collects similarly located [VectorSort*] is displayed when this has been
ON
◊
line data and sorts it. Plotting time is shortened by selected.
eliminating wasted pen movement.
WaitingTime
When data has not been received for more than ten
Refer to “Replotting” on page 8 for further details.
ON
♦
seconds, this function judges that the data for
plotting one complete page has been received.
X-Axis
When plotting in alignment with a grid, such as
For further details, refer to “Correcting the
—
—
when plotting on section film, this sets the X-axis distance” on pages 28 and 32.
distance from the base point.
X-Point
This aligns the coordinate axis in the X-axis
Maximum rotation is five degrees.
—
—
direction during plotting with the coordinate axis
For further details, refer to “Setting the X
in the X-axis direction of the loaded sheet.
correction point” on pages 27 and 31.
This can be used to make adjustment when the
loaded sheet is not perfectly straight, or when the
grid markings of a section film or the like are
slightly uneven because of shrinkage or expansion
of the material.
Y-Axis
When plotting in alignment with a grid, such as
For further details, refer to “Correcting the
—
—
when plotting on section film, this sets the Y-axis distance” on pages 28 and 32.
distance from the base point.
Y-Point
This aligns the coordinate axis in the Y-axis
Maximum rotation is five degrees.
—
—
direction during plotting with the coordinate axis
For further details, refer to “Setting the Y
in the Y-axis direction of the loaded sheet.
correction point” on pages 27 and 31.
This can be used to make adjustment when the
loaded sheet is not perfectly straight, or when the
grid markings of a section film or the like are
slightly uneven because of shrinkage or expansion
of the material.
A plus sign (*) is displayed when the menu for setting only ON/OFF is set to ON.
Summary of Contents for DPX-2700A
Page 1: ...USER S MANUAL DRAFTINGPLOTTER DPX 3700A DPX 2700A ...
Page 10: ...viii MEMO ...
Page 59: ...R8 991012 ...