5. Troubleshooting
Error Message
Remark
#1 Command Not
When an unrecognizable command is transmitted, that command is ignored.
Recognized
#2 Wrong Number
When the number of parameters supported by a command is incorrect, that
of Parameters
command is ignored.
#3 Out of
When a parameter value is outside that parameter's range, it is ignored.
Parameter Range
#5 Unknown
When a character set code not included in the current character set is specified, that character
Character Set
is ignored. Use [Character] on the menu to search for available character set codes.
#6 Position
The overflow positions are ignored.
Overflow
#7 Polygon Buffer
The overflow was ignored.
Overflow
#10 Output
When executing an output request command, another output request command was sent (only
Request Overlap
the first one received is effective).
#11 I/O Command
When a device control command error has occurred, that command is ignored.
Not Recognized
#12 Wrong I/O
This error message occurs when an unsuitable device control command parameter is specified
Parameter
(the initial value is set for the parameter which generated the error).
#13 Out of I/O
This error message occurs with overflow of a device control command parameter.
Parameter Range
#14 Too Many
This error message occurs when there are too many parameters or when not terminated using a
I/O Parameters
colon.
#15 Error in I/O
This error message occurs when a framing error, parity error, or overrun error occurs
Transmission
duringdata transmission.
#16 I/O Buffer
This error message occurs when the I/O buffer overflows. (Under such transmission.
Overflow
circumstances, the plotter cannot perform plotting correctly.)
#17 Baudrate
This error message occurs when there is an error with the setting for the rate of Turn off the
Error
power and then turn it on again before transmitting data from the computer again.
#18 I/O Error
An error other than those listed above has occurred.
Indeterminate
Error Message
Other Message
Message
Notes
Motor Error
Plug in the power supply again.
Power ON Again
Too Big Data
The amount of cutting data exceeds data buffer capacity.
Can not Replot
Pen Change : Pen No.
If the tool does not need to be changed, press the key without making any
Press Pause key
changes. If you turn [TOOL STOP] to [OFF] in the control panel, this display will
no longer appear.
If an error message is displayed, the display can be cleared by pressing the
key.
If the error message concerns an instruction, the message itself will be cleared by pressing the
key, but the error
itself will not be cleared. In addition, if the error message is ignored in the unit is operated, operations past that point will
not be corrected. Sending an OE instruction from the computer or turning off the power to the unit will clear everything.