18
Menu
Operation Procedure : The
key toggles between [ON] and [OFF].
OFF
Even if a pen change command is received, the cutting machine does not stop, instead automatically changing
the parameters to that of the tool number specified in the received command.
ON
When a pen change command is received, the tool carriage moves to the lower left corner of the cutting table
and operation stops. This is when the tool is to be changed. Press
to continue operation. Doing so
returns the tool carriage to its location when operation was halted, and cutting resumes when a tool signal is
received.
Tool Stop
Default
VSCommand[OFF]
ToolStop[ON]
• Movement settings for tool replacement
• Confirm the position of the tool carriage
Key Operation from Top Menu:
Press the
key three times.
Menu
Coordinate Display
CoordinateDisplay
X: 0mm Y: 0mm
• The displayed coordinates change as the tool carriage moves. The position of the carriage can be confirmed as a
coordinate value.
Default
Menu
Unit
Unit[mm]
I/O Calibrate
Default
mm
Operation Procedure : The
key toggles between [mm] and [Step].
• When this display is switched, the setting for sheet size, the offset setting, and the units used to show the coordinate
display also change.
Key Operation from Top Menu:
Press the
key two times and then the
key.
Menu
Operation Procedure: Press the
key to display the screen for carrying out Default .When the
key is
pressed, [No] is selected and the display returns to the previous screen. Pressing the
key causes [Yes] to be selected and all settings default to values preset at the factory.
Default
Default
Instruc Submenu
Default
• When you choose [DEFAULT], all previously set tool number parameters are erased.
Key Operation from Top Menu:
Press the
key two times and continue by the pressing the
key and
key.
• Changing the unit of measure for display
• How to reset all settings to the factory default settings
Key Operation from Top Menu:
Press the
key two times.
Summary of Contents for CAMM-1 PNC-1610