background image

SERVICE NOTES

Issued by RJA

CC-OKN

Jun. 2021

AE-30

Cautionary Notes

Before beginning the procedure, please read through this document. The matters described may differ 
according to the model.

About the Serial Number

On this product, the serial number is displayed in the Test Mode and is written 
to the main board using the dedicated application. The serial number is also 
written on the sticker affixed inside the battery box.

Back Up User Data!

User data may be lost during the course of the procedure. Refer to 

Data 

Backup and Restore Operations

 (p. 6) in the Service Notes and save the data. 

After completing the procedure, restore the backed-up data to the product.

Parts List

A component whose part code is ******** will not be supplied as a service part 
because one of the following reasons applies.

Because it is supplied as an assembled part (under a different part code).

Because a number of circuit boards are grouped together and supplied as 
a single circuit board (under a different part code).

Because supply is prohibited due to copyright restrictions.

Because reissuance is restricted.

Because the part is made to order (at current market price).

Because it is carried in electronic data on the Roland web site.

Because it is a package or an accessory irrelevant to the function 
maintenance of the main body.

Because it can be replaced with an article on the market. (battery or etc.)

Because it is sold as a product.

Circuit Diagram

In the circuit diagram, “NIU” is an abbreviation for “Not in Use,” and 
“UnPop” is an abbreviation for “Unpopulated.” They both mean non-mounted 
components. The circuit board and circuit board diagram show silk-screened 
indications, but no components are mounted. 

There are cases that the circuit diagrams are omitted. This omission will 
happen to the highly integrated digital circuit boards (e.g. Main Board etc) that 
are virtually impossible to repair nor analyze.

Roland Japan Warranty

Please send the problem report with followings when the defect occurred 
within one year from production and within one month from the first 
customer’s purchase.

Model name: 

Serial number: 

Version: 

Purchase date by the first customer: yyyy/mm/dd

Symptom: 

Frequency: always, sometimes or seldom

Confirmed the symptom at your service dept: Yes/No

Please send the problem report to [email protected].

Summary of Contents for AE-30

Page 1: ...ons Because reissuance is restricted Because the part is made to order at current market price Because it is carried in electronic data on the Roland web site Because it is a package or an accessory i...

Page 2: ...r Amplifier Power Output 1 5 W x 2 Speakers 2 8 cm x 2 Power Supply AC adaptor DC 5 7 V Rechargeable Ni MH battery AA HR6 sold separately x 6 Current Draw 915 mA Battery life for continuous use Rechar...

Page 3: ...the acetate tape 40122812 so as to cover the locations where the battery terminals and the wirings are soldered fig kumitate tape eps Replacing the Bender Board When replacing the Bender Board verify...

Page 4: ...umitate tb4 e eps Attaching the Panel Center Board When securing the Panel Center Board to the Top Case use two types of screws Use the silver screw 40011267 at the location where 6 is printed near th...

Page 5: ...s g Plain View Fig A View A3 A4 and A5 Also all of No 1 Key Cap A are fixed to No 2 R Key A and No 3 Key Cap B is fixed to No 4 R Key B with adhesive 40122445 fig kumitate button eps About Peripheral...

Page 6: ...tem Backup screen 9 Turn off the power and disconnect the USB memory device Restoring System Settings 1 Hold down MENU and turn on the power Continue to hold down MENU until the Roland logo disappears...

Page 7: ...5 Turn off the power If the message to reset the power is displayed follow it Writing Serial Number When Main Board has been replaced follow the procedure described below to write the serial number in...

Page 8: ...s on the computer just described MIDI OX is available at the following website http www midiox com Mouth piece for test Kindly prepare a product OP AE10MP or OP AE10MPH for inspection purposes Enterin...

Page 9: ...m contrast intermediate contrast maximum 2 Press to advance to the next test item 5 LED This checks whether each LED lights up correctly fig test5 eps The power LED lights up orange and the LED goes o...

Page 10: ...e of the screen is within the range from 110 to 140 10 Press Bend 152 170 is displayed on the screen 11 Flip the bender all the way to the back and verify that the value displayed on the lower line of...

Page 11: ...hecks the operations of the on board speaker the PHONES and OUTPUT jacks fig test8 eps 1 Verify that sounds are coming out from the on board speaker L not from the on board speaker R fig test8 2 eps 2...

Page 12: ...d set Bluetooth on 3 On the Bluetooth setting screen touch AE 30 Audio When pairing succeeds Connected is displayed on the right of AE 30 Audio and the screen display of AE 30 is changed from A2DP to...

Page 13: ...ower is turned off fig test14 eps Return the power switch to the off position This completes the testing in the Test Mode Carry out the following tests in the normal mode 1 Battery Test 1 If an AC ada...