Performing a Factory Reset

This returns the system settings to their factory-default values.

* Performing this operation does not erase the scene settings that the user is 

registered.

1.

Press 

MENU

.

The 

MENU

 screen is displayed.

2.

Press 

 or 

 to select 

Factory Reset

 and press 

MENU

.

A confirmation screen is displayed.

3.

To execute the factory reset, press 

 to select 

YES

. To cancel it, press 

 to select 

NO

.

Pressing  

makes 

Executing...

 appear on the screen, and the factory 

reset is executed. When the operation has finished, 

Complete

 appears 

and then 

Turn off the power

 is displayed with flashing.

4.

Reset the power.

Updating the System

Items Required

Computer (running Windows)

USB memory device (Type-C)

USB cable (Type C <--> Type A)

Update file (obtained via Service Net)

Procedure

1.

Copy the update file (

AE-30_UPA_up.bin

) to the root folder of the USB 

memory device.

2.

Turn off the power.

3.

Connect the USB memory device just described to the 

USB

 connector on 

the unit.

4.

Hold down 

OCT+2

 and 

OCT-2

 and turn on the power.

fig.oct.eps

The update starts automatically. 

When 

Please power off

 is displayed, the updating has finished.

* Never turn off the power while the update is in progress.

5.

Turn off the power. If the message to reset the power is displayed, 
follow it.

Writing Serial Number

* When Main Board has been replaced, follow the procedure described below to 

write the serial number into the unit.

Items Required

Computer (running Windows)

USB cable (Type C <--> Type A)

AE-30 driver

* Obtain this from the following web page, and install it on the computer just 

described.
https://www.roland.com/global/

Application for writing serial number (AE-X Serial Writer.exe)

* Obtain this from the 

Related Information

 on the top page of Service Notes.

Procedure

1.

Connect the AC adaptor. 

2.

Turn on the power.

3.

With the unit being powered up, press the following buttons (

X

,  

and 

).

fig.testmode.eps

Continue to hold down the buttons above until the following screen 
appears.

fig.testmode-screen.eps

4.

Press 

 three times.

The screen like the following appears.

fig.testmode-serial1.eps

5.

Press 

MENU

.

The screen like the following appears.

fig.testmode-serial2.eps

6.

Note the serial number (7 characters) displayed on the screen.

* The serial number is also written on the sticker affixed inside the battery box.

7.

Turn off the power.

8.

Using the USB cable, connect the 

USB

 connector to the computer.

9.

Carry out steps 

2

 and 

3

 to enter the Test Mode.

OCT+2

OCT-2

T-- 

01/01 

 TEST SELECT

1/9

Service 1

Push [MENU] To Start

T-- 

01/01 

 TEST SELECT

4/9

Serial Read

Push [MENU] to Start

T-S 

01/02 

 SERIAL

1/1

Serial No.  [*******]

Summary of Contents for AE-30

Page 1: ...ons Because reissuance is restricted Because the part is made to order at current market price Because it is carried in electronic data on the Roland web site Because it is a package or an accessory i...

Page 2: ...r Amplifier Power Output 1 5 W x 2 Speakers 2 8 cm x 2 Power Supply AC adaptor DC 5 7 V Rechargeable Ni MH battery AA HR6 sold separately x 6 Current Draw 915 mA Battery life for continuous use Rechar...

Page 3: ...the acetate tape 40122812 so as to cover the locations where the battery terminals and the wirings are soldered fig kumitate tape eps Replacing the Bender Board When replacing the Bender Board verify...

Page 4: ...umitate tb4 e eps Attaching the Panel Center Board When securing the Panel Center Board to the Top Case use two types of screws Use the silver screw 40011267 at the location where 6 is printed near th...

Page 5: ...s g Plain View Fig A View A3 A4 and A5 Also all of No 1 Key Cap A are fixed to No 2 R Key A and No 3 Key Cap B is fixed to No 4 R Key B with adhesive 40122445 fig kumitate button eps About Peripheral...

Page 6: ...tem Backup screen 9 Turn off the power and disconnect the USB memory device Restoring System Settings 1 Hold down MENU and turn on the power Continue to hold down MENU until the Roland logo disappears...

Page 7: ...5 Turn off the power If the message to reset the power is displayed follow it Writing Serial Number When Main Board has been replaced follow the procedure described below to write the serial number in...

Page 8: ...s on the computer just described MIDI OX is available at the following website http www midiox com Mouth piece for test Kindly prepare a product OP AE10MP or OP AE10MPH for inspection purposes Enterin...

Page 9: ...m contrast intermediate contrast maximum 2 Press to advance to the next test item 5 LED This checks whether each LED lights up correctly fig test5 eps The power LED lights up orange and the LED goes o...

Page 10: ...e of the screen is within the range from 110 to 140 10 Press Bend 152 170 is displayed on the screen 11 Flip the bender all the way to the back and verify that the value displayed on the lower line of...

Page 11: ...hecks the operations of the on board speaker the PHONES and OUTPUT jacks fig test8 eps 1 Verify that sounds are coming out from the on board speaker L not from the on board speaker R fig test8 2 eps 2...

Page 12: ...d set Bluetooth on 3 On the Bluetooth setting screen touch AE 30 Audio When pairing succeeds Connected is displayed on the right of AE 30 Audio and the screen display of AE 30 is changed from A2DP to...

Page 13: ...ower is turned off fig test14 eps Return the power switch to the off position This completes the testing in the Test Mode Carry out the following tests in the normal mode 1 Battery Test 1 If an AC ada...

Reviews: