8
Jun. 2021
AE-30
10.
Press
twice.
The screen like the following appears.
fig.testmode-serial3.eps
11.
Press
MENU
.
The screen like the following appears.
fig.testmode-serial4.eps
12.
On the computer, start AE-X Serial Writer.exe.
13.
Verify that
AE-30
are displayed at
MIDI IN Devices
and
MIDI OUT
Devices
in the application screen on the computer.
* If
AE-30
is not displayed, check whether the USB driver is installed correctly.
14.
Input the serial number written down in step
6
to
Input No.
.
* At this time, input
21
first, then input the serial number. The serial number you
input (except
21
) is displayed next to
Write No.
.
fig.testmode-serial5.eps
The screen on the AE-30 is switched as shown below and the serial
number is written.
fig.testmode-serial6.eps
15.
Turn off the power.
Test Mode
Items Required
•
AC adaptor (PSD series)
•
Computer (running Windows)
•
USB cable (Type C <--> Type A)
•
MIDI cable
•
Audio cable (with miniature stereo phone plug x 1)
•
USB memory device (Type-C)
•
Headphones (A device equipped with a 1/4-inch phone/miniature
phone adaptor plug can be useful.)
•
Ni-MH battery (AA, HR6) x 6
•
Mobile device capable of Bluetooth (iPhone or Android)
•
Software program capable of Bluetooth MIDI (Web MIDI Browser or the
like)
* Install this on the mobile device just described.
•
MIDI sequence program (MIDI-OX or the like)
* Install this on the computer just described.
* MIDI-OX is available at the following website.
http://www.midiox.com/
•
Mouth piece (for test)
* Kindly prepare a product (OP-AE10MP or OP-AE10MPH) for inspection
purposes.
Entering the Test Mode
1.
Connect the AC adaptor.
2.
Turn the
SCENE CATEGORY
knob and the
TRANSPOSE
knob all the
way counterclockwise.
3.
Set the
MIDI CONTROL
switch to
OFF
.
4.
Turn on the power.
5.
With the unit being powered up, press the following buttons (
X
,
and
).
fig.testmode.eps
Continue to hold down the buttons above until the following screen
appears.
fig.testmode-screen.eps
6.
Press
MENU
.
The unit enters the first item of the Test Mode (
Quitting the Test Mode
Turn off the power.
Selecting Test Items
1.
After entering the Test Mode, press
MENU
twice.
The
TEST
MENU
screen is displayed.
fig.testmode-select.eps
2.
Press
or
to select the test item.
3.
Press
MENU
.
The screen for executing the selected test item is displayed.
When pressing
MENU
again, the unit goes back to the
TEST MENU
screen.
Test Items
The following tests are executed in the normal mode.
T--
01/01
TEST SELECT
3/9
Serial Write
Push [MENU] to Start
T-S
01/02
SERIAL
1/3
Input
21*******
T-S
01/02
SERIAL
0/1
Write Data OK[*******]
T--
01/01
TEST SELECT
1/9
Service 1
Push [MENU] To Start
TEST MENU [Ent]
>01.VERSION
02.DEVICE
03.WAVE ROM