RP208CN User’s and Installer’s Manual Page 36
6
Door Chime
Assigned to an opening which, when violated during the disarmed,
will cause the system's keypad(s) to beep once during an alarm,
the external sounding device will annunciate continuously, without
interruption. When alarm occurs during armed system only the
external sounder will be activated.
For example
:
if the zone 1need to set to be entry/exit delay zone, and need the
exterior alarm intermittent sound at the same time keypad buzzer sound when
need to alarm, then input 14 in location 14. If the 3 zone need to set to be
active zone, and need the exterior alarm intermittent alarm, then input 32 in
locate 16. The zone characteristic of default:
Zone 1: Entry/Exit Delay Zone; zone type is 11
Zone 2: Instant (Intrusion) Zone; zone type is 21
Zone 3: Instant (Intrusion) Zone; zone type is 21
Zone 4: Panic Zone; zone type is 70
Zone 5: Fire Zone; zone type is 52
Zone 6: Tamper Zone; zone type is 61
Zone 7: Interior Zone; zone type is 41
Zone 8: Interior Zone; zone type is 41
Special Zones Suggestion:
a. Zone 5 is reserved as a Fire Zone, Supports Smoke Detectors and/or Gas
Detectors. A fire zone cannot be disabled or bypassed. For fire zone the
recommended (default) zone sound is "External sounder pulsed". However it
is possible to change the zone sound and type to any of the ones provided
in the previous list.
b. Urgency zone alarm doesn’t result the siren sound but calling to the CMS or
follow-me numbers.
c. Zone 6 on the RP208CN is reserved as a Tamper Zone. This zone can be
programmed to any zone type. If the zone was programmed as Tamper, in
violation, a Tamper Code report will be sent and the Tamper LED on the
keypad will light up.
Utility Outputs- Event and Result
:
Locations22, Default 00
The RP208CN supports one open collector Utility Output (derived between the