RP208CN User’s and Installer’s Manual Page 18
12
-
“BAT+” the anode of the standby power
13/14
-
“AC” low-tension entry port for AC power (AC16.5V)
15
-
the port for ground
16
-
“BELL+” connect to the anode of detector
17
-
“BELL-” connect to cathode of detector
18
-
“UO” Utility Outputs
19/20
-
“AUX” connect to the anode of detector(s) “DC12V+”
22/25/28/31
-
“COM” the communal port. In general, the port “COM”
should connect to of the anode of detector(S) “DC12V-” and one port
of the “ALARM” and “TAMPER”
21
-
“Z1” the port for zone 1, defaults as Entry/Exit Delay Zone. Connect
to one port of “ALARM” on the detector.
23/24
-
“Z2” for zone 2 and “Z3” for zone 3. Defaults as Instant (Intrusion)
Zone.
26
-
“Z4” the port for zone 4 defaults as Panic Zone. Suit for connect with
a panic button
27
-
“Z5” the port for zone 5 defaults as fire zone. Suit for connect with a
Gas Detector or a Smoke Detector.
29
-
“Z6” the port for zone 6 defaults as tamper zone. The user should
connect it with one of the port “TAMPER” on detector.
30/32
-
“Z7” the port for zone 7 and “Z8” zone 8, both of them are default
ed as Interior Zone. When arm by [STAY], the Interior Zone won’t be
armed.
33
-
“GRN” the port should connect to the green line on the keypad.
34
-
“YRL” the port should connect to the yellow line on the keypad.
35
-
“BLK” the port should connect to the black line on the keypad.
36
-
“RED” the port should connect to the red line on the keypad.