Cleaning the Device | 8
Power Chuck DURO-A
47 / 52
8
Cleaning the Device
CAUTION
Skin irritations due to contact with lubricants.
Lubricants may cause irritations in the event of contact with the
skin.
Ø
When handling the
power chuck
, wear safety goggles, long
work clothes and gloves.
Ø
Avoid skin contact with lubricants.
The power chuck must be cleaned with a broom or brush before each as-
sembly and every time a jaw and workpiece is replaced.
Cleaning with compressed air or a high-pressure cleaner is not permitted.
8.1
Personal Protective Equipment and Personnel Qualification
When working on and with the power chuck DURO-A, personal protective
equipment must be worn. The owner is responsible for providing personal
protective equipment.
▪ Personal protective equipment must be in perfect condition when carry-
ing out work. Defective safety equipment is to be replaced immediately.
▪ Observe information on personal protective equipment posted in the
working area.
▪ During
rotational operation
of the power chuck DURO-A,
no
protective
gloves are to be worn! Hand protection is only to be worn during trans-
port, assembly and maintenance and as long as the power chuck
DURO-A is at a standstill.
Wear protective gloves
Wear safety goggles
Wear safety shoes
Work on and with the power chuck may only be carried out by qualified oper-
ating and specialist personnel (see
Qualification of Operating and Spe-
).
Summary of Contents for DURO-A