Instructions Handbook 1179.2948.02 ─ 01
5 = Connector [X26] (RS-232, 9-pin D-Sub, female) for remote door control via a serial port
6 = Connector [X32] (binder socket, 3-way, female) for monitoring the door status
7 = Connector [X21] (25-pin D-Sub, male) for push-button door control
8 = Socket for 24
V
DC power supply unit (center pin: positive voltage)
9 = Connector [X20] (LAN) for remote door control via Ethernet
The 24
V
DC socket (8) serves for power input from the external power supply unit
(included in delivery). See
"To prepare the power connection"
The D-Sub 25-pin connector [X21] (7) allows local control of door activity by the exter-
nal
Chapter 7.3.2, "Push-Button Door Operation"
on page 44. For the connector's safety cap, see
.
The RS-232 connector [X26] (5) and the LAN connector [X20] (9) allow computer-
based remote control of door activity by an operator or by software. Use either the
RS-232 connector or the LAN connector. See
Chapter 8.3, "Door Operation Commands"
The binder connector [X32] (6) allows monitoring the door's position (open or closed
state), in addition to the door status indication by the light in the
. The binder connector's pins are assigned as follows: pin
1 = door open, pin
2 =
chassis ground, pin
3 = door closed.
The quick-coupling plug (4) for compressed air is delivered with an additional push-pull
adapter to 6
mm flexible tubing.
The 24
V
DC socket [X1] serves for power input from the external power supply unit
(included in delivery). See
"To prepare the power connection"
The LAN connector [X2] and the RS-232 connector [X3] allow computer-based remote
control of door activity by an operator or by software. Use either the RS-232 connector
or the LAN connector. See
ter 8.3, "Door Operation Commands"
To connect a control system
For local manual control of the door, connect the push-button switch unit (
) to
the chamber.
For remote control, connect the chamber to your control system. Depending on your
system requirements, you can use the Ethernet (LAN) or RS-232 interface.
1. For
manual
control by the push-button switch unit (
), connect this unit as
follows:
Connecting to Control and Power