Installation and Commissioning
R&S
®
TS7124AS
27
Instructions Handbook 1179.2948.02 ─ 01
6.3.1
Table Mounting
Use a support that meets the requirements. Make the support robust and safe.
To mount the chamber on the support
1.
WARNING!
The door of the chamber is heavy and can move. If the door slides
open while you lift the chamber, the center of gravity shifts. The door hitting its end
position results in a powerful thrust.
Ensure that the metal safety latch in the top left corner of the chamber's door (
) secures the door against unintentional opening.
2.
WARNING!
Risk of injury due to heavy weight. See
Chapter 5.1, "Lifting and Carry-
Lift the chamber at its handles with at least 2 people and place it on the support.
3. Position the chamber with its front edge at least 50
mm back from the front edge of
the table.
This distance leaves room for the front mounting brackets, see
.
4. Fix the chamber in place with mounting brackets (included in delivery):
a) Place the four mounting brackets at the lower front and rear corners of the
chamber.
The black arrows in
show the positons for the mounting brackets.
b) Position each bracket so that its notch (see red arrow in top left picture) is at
the upper end, latching into the bore on top of each screw hole.
c) Screw each bracket to the chamber.
d) Screw each bracket to the table.
Figure 6-2: Positions of the mounting brackets for fixing the chamber to its support
5. Remove the metal safety latch (
) from the top left corner of the chamb-
er's door.
Keep the safety latch for future use.
Mounting the Chamber