Function Description
R&S
®
TS-PSAM
25
User Manual 1142.9878.12 ─ 12
Operation
The following functions are available to configure the trigger logic:
rspsam_trig_ConfigureOutput
rspsam_trig_ConfigureSignal
rspsam_trig_Abort
rspsam_trig_EnableOutput
rspsam_trig_SendSoftwareSignal
5.2
Function Description of the R&S TS-PDC Module
On this topic, see also
.
The DC/DC converter is configured as a primary reference DC/DC converter. The input
voltage (5 VDC) is transfered to two secondary potentials and rectified to the nominal
voltage by line controllers. The status of the output voltage is displayed in each case
by an LED.
The following DC voltages are generated:
●
+15 VDC, 0,5A (2x)
●
-15 VDC, 0,5A (2x)
●
+5 VDC, 0,5A (2x)
●
+3,3 VDC, 0,25A (2x)
Function Description of the R&S TS-PDC Module