Door Release or Door Lock
Electric device used to lock/unlock a door. Typically it can be a door strike, solenoid lock or
magnetic lock.
Identifier
The physical item or method which is used for identification of users. It can be a proximity card, a
PIN code, a finger template etc. In some cases identifier may consist of two or more items required
for a single identification procedure. For example when option
Card and PIN
is active then
Identifier=Card+PIN.
Identification Mode
The method used for identification of users, it can be
Card or PIN
,
Card and PIN
,
Card only
,
PIN only
etc.
Memory Reset
The procedure which clears contents of device’s memory and restores default (factory) settings.
PRT Series Readers
The PRT reader’s family developed and manufactured by Roger.
Restart
The situation when device goes through the initialization procedure, the same as when it is
powered up.
Roger Access Control System (RACS)
The access control system which consists of PR series access controllers developed and
manufactured by Roger.
Access Control Unit (ACU)
The logic device which provides access control, usually it is an access controller.
XM-2 I/O Extension Module
The remote I/O extension module for RACS system. The XM-2 provides two NO/NC inputs and two
relay outputs.
Full Standalone Mode
The operation mode in which reader autonomously controls a door passage. When operating in
Full
Standalone Mode
the PRT-EM reader requires the remote XM-2 extension module, also in this
mode it can operate with another (second) PRT series reader thus providing two-way passage
control.
Simple Standalone Mode
The operation mode in which reader independently controls a door passage. When in
Simple
Standalone Mode
the PRT-EM reader uses its internal I/O lines as general purpose I/Os but is not
capable to operate with XM-2 I/O module and/or second PRT series reader.
RACS Interface
The electrical interface and addressable protocol developed by Roger. This interface is implemented
in access readers and controllers manufactured by Roger. The RACS interface uses two
communication lines (CLK and DTA) and proprietary communication protocol capable to address up
to 16 devices.
EPSO Protocol
The addressable, half duplex, serial communication protocol developed by Roger. This protocol
allows a host device (PC or controller) for direct control of the reader’s hardware through the set of
remote commands.
Summary of Contents for PRT12EM
Page 43: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 43 from 59...
Page 50: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 50 from 59...
Page 51: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 51 from 59...
Page 52: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 52 from 59...
Page 53: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 53 from 59...
Page 54: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 54 from 59...
Page 55: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 55 from 59...
Page 56: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 56 from 59...
Page 57: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 57 from 59...
Page 58: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 58 from 59...