205
Disarming by input
Reader has been disarmed by input line
[24]:
Arming/Disarming Key Switch
006
Summer time
Clock has been pushed backward by 1 hour
007
Winter time
Clock has been pushed forward by 1 hour
109
Door bell
Door bell indication triggered
300
Forced entry
Door opened in unauthorized way
304
Door ajar
Door open to long
301
Prealarm
Five consecutive attempts to enter wrong PIN or card
within 5 minutes – Prealarm signaling started
112
Unknown card
The unknown card has been entered (card code)
113
Unknown PIN
The unknown PIN has been entered (PIN code)
003
User Programming
Reader switched to
User Programming
mode
004
Installer Programming
Reader switched to
Installer Programming
mode
005
Online mode
Reader switched to online communication mode with PC
000
Reader restarted
Reader passed through initialization procedure (the
same as during power on)
001
Clock cleared
The internal clock of the reader has been cleared
002
Clock changed
The internal clock of the reader has been programmed
302
Tamper Alarm
Reader entered
Tamper Alarm
state
303
Intruder Alarm
Reader entered
Intruder Alarm
state
305
Duress Alarm
Reader entered
Duress
Alarm
state
999
Unknown event
Event code doesn’t fit any known event – error in data
5.13.
R
EAL
T
IME
C
LOCK
The PRT-EM is equipped with Real Time Clock (RTC) predefined for 100 year. This clock is used to
append a time stamp to every event recorded by the reader. The RTC clock has not battery back-
up so it resets to 2000-01-01 00:00 whenever power is off. When required, the RTC can be
configured to switch automatically to winter or summer time.
Note: Normally, when reader’s Real Time Clock is unset (or lost due to lack of power supply)
reader continues its operation however this can be changed. When option
Real Time Clock
Control
is active reader will stop its operation till moment when clock will be programmed again
(see Installer Programming, function
[78]
.
5.14.
T
IMERS
Reader uses several timers, each timer is assigned to specific function and can be programmed in
seconds or minutes.
ID
Timer
Defaults
Function
0
Door Unlock Time
(00-99 sec./min.)
4 sec.
Defines time for which door lock will be released.
This timer controls following outputs:
[41]: Door
Lock
,
[42]: Door Lock Exit
,
[43]: Door Lock
Entry.
Summary of Contents for PRT12EM
Page 43: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 43 from 59...
Page 50: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 50 from 59...
Page 51: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 51 from 59...
Page 52: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 52 from 59...
Page 53: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 53 from 59...
Page 54: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 54 from 59...
Page 55: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 55 from 59...
Page 56: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 56 from 59...
Page 57: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 57 from 59...
Page 58: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 58 from 59...