[73][S][KL] – Programming Duress Timer, S=0..1, KL=00..99, default: S=1 KL=03
This timer defines duration time for
Duress Alarm
. When S=0 and KL=00 alarm time will be
unlimited - till moment when reader changes its arming mode. Program S=0 for seconds or S=1
for minutes. Setting S=1 and KL=00 is forbidden.
[74][S][KL] – Programming LED STATUS Timer, S=0..1, KL=00..99, default: S=0 KL=00
This timer defines time for which LED STATUS will be active after since the moment when arming
mode was changed. Program S=0 for seconds or S=1 for minutes. Setting S=0 and KL=00 or S=1
and KL=00 is forbidden.
Note: This timer has been used only when LED STATUS Masking function is activated.
[75][L] – Programming keypad backlight level, L=0..5, default: L=3
The L digit defines keypad backlight level. Program: L=0 for 0% (backlight is off), L=1 for 20%,
L=2 for 40%, L=3 for 60%, L=4 for 80% or L=5 for 100% (maximum backlight).
[76][L] – Programming buzzer loudness level, L=0..5, default: L=3
The L digit defines buzzer loudness level. Program: L=0 for 0% (sound is off), L=1 for 20%, L=2
for 40%, L=3 for 60%, L=4 for 80% or L=5 for 100% (maximum sound).
[77][L] – Programming LED STATUS Masking function, L=0..1, default: L=0
When L=0 LED STATUS continuously indicates current arming mode of the unit. When L=1 LED
STATUS is normally in neutral mode (sequentially switches from green to red and vice verso
however whenever arming mode is changed or unit is restarted it lights up for time defined by LED
STATUS timer and then switches to neutral mode again.
Note: Use this function in case you want to keep secret current arming mode of the unit.
[78][L] – Programming Real Time Clock Control option, L=0..1, default: L=0
When L=0 reader continues normal operation even when reader’s clock is unset or lost. When L=1
reader stops its normal operation however user can use keypad to set clock and restore normal
reader operation.
Note: When option is active and clock is unset or lost, all LED-s are pulsing and reader stops its
normal operation. In order to restore normal operation set the clock either manually or from PC.
[79][D] – Programming Duress function, D=0..1, default: D=0
When D=0 reader will not either recognize nor signal enroll of PIN under duress. When D=1
entering a valid PIN code with last digit modified by +/-1 will be treated as under duress and will
cause signaling on output line (when programmed).
[80] [SSWW] – Programming Winter/Summer time change
SS: Day in March when time is changed from Winter to Summer (clock is moved from 2:00 to
3:00). Setting SS=00 deactivates automatic time change while programming SS=99 makes device
will change Winter/Summer time on last Sunday of March.
WW: Day in October when time is changed from Summer to Winter (clock is moved from 3:00 to
2:00). Setting WW=00 deactivates automatic time change while programming WW=99 makes
device will change time on last Sunday of October.
[81][ PIN][#][Card] – Programming new MASTER user
Programs PIN and card for MASTER user. Optionally, program [81][PIN][#][#] to omit card
programming or [81][Card] to omit PIN programming.
[82][PIN][#][Card] – Programming new INSTALLER PIN and/or card
Programs PIN and card for Installer user. Optionally, program [82][PIN][#][#] to omit card
programming or [82][Card] to omit PIN programming.
Summary of Contents for PRT12EM
Page 43: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 43 from 59...
Page 50: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 50 from 59...
Page 51: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 51 from 59...
Page 52: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 52 from 59...
Page 53: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 53 from 59...
Page 54: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 54 from 59...
Page 55: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 55 from 59...
Page 56: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 56 from 59...
Page 57: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 57 from 59...
Page 58: ...PRT EM Series Readers fv 1 29 and 2 29 Rev J doc 2012 01 05 Page 58 from 59...