EN
90
19
Mechanical release
In the event of a fault or mains power loss, the gate may be released and opened manually. For systems with
BH30/804/R the gate can be moved by hand without unlocking it.
If the gate releases with the controller unit powered, the message
6WRS
ƽEWLIWSRXLIHMWTPE]
For further information, refer to the locking/release operation in the manual of the
BH30
or
BM30
automation system.
• When the release system is restored to the normal operating position, if the gate is not completely open or
completely closed the next time a command is received, the control initiates a position recovery procedure (see
chapter 20).
• Activating one of the two limit switches immediately reacquires the position.
20
Position recovery mode
After a mains power outage or after mechanically releasing the gate, if the gate is not completely open or
completely closed the next time a command is received, the control initiates a position recovery procedure:
• The gate starts a low speed manoeuvre.
•
8LIƽEWLMRKPMKLXƽEWLIW[MXLEHMJJIVIRXHYX]G]GPIXLERRSVQEPWSRWSJJ
• The control unit recovers the installation data during this procedure. Warning! During this procedure, do not use
any controls until one of the two limit switches is reached.
• Activating one of the two limit switches immediately reacquires the position.
21
Initial testing
8LIXIWXMRKQYWXFITIVJSVQIHF]UYEPMƼIHXIGLRMGEPTIVWSRRIP
The installer is required to measure impact forces and select on the control unit
the appropriate speed and torque values to ensure that the motorised door or gate
VIQEMRW[MXLMRXLIPMQMXWHIƼRIHF]XLIWXERHEVHW)2ERH)2
Make sure that the provisions in Chapter 1 "GENERIC WARNINGS are observed.
• Turn on the power supply.
• Check that all connected controls are working correctly.
• Check that the release handle works correctly. The message
6W23
QYWX ƽEWL SR XLI
display.
• Check travel and deceleration.
• Check that the impact force is correct, in compliance with EN 12453 and EN12445.
• Check that the safety devices are activated correctly.
• If the battery kit is installed, disconnect from mains and check that the batteries are
working.
• Disconnect from mains power and disconnect the batteries (if used), then reconnect.
Starting with the gate stopped in an intermediate position, check that the position
recovery procedure is completed correctly for both the open and closed positions.
• Check that the limit switches are set correctly and function correctly. Adjust the position
of installation of the motor if necessary.
• Check that there is a gap of at least 2-3 cm between the gate and the mechanical stop at
the end of the manoeuvre.
• Only for BH30/804/R.
Check that without mains or battery voltage, when moving the leaf
by hand, the control unit is switched on and that the display shows the "
6(/)
" message.
• Only for BH30/804/R.
If there are batteries, disconnect the mains power and check that
the display shows
E$WW
. If
6(/)
is displayed followed by
$/,
, change the red and black
GEFPIWGSRRIGXMSRXSXLI43;)6-2XIVQMREPWXVMTWEWMRHMGEXIHMRƼK
Summary of Contents for B70/1DC
Page 4: ...4 FW r1 65 ...
Page 5: ...5 1 BH30 BM30 A A A A B A A B ...
Page 6: ...6 A B A 2 4 5 BH30 Scheda ricarica batteria B71 BC B71 BC battery charger ...
Page 8: ...8 4 BH30 CAVO MOTORE MOTOR CABLE ...
Page 20: ...20 17 PR1 PR2 L1 L2 PR1 PR2 Canali radio Radio channels ...
Page 21: ...21 n e ro b la c k gr igi o g rey 18 BH30 ...