EN
85
16
Safety input and command status (TEST mode)
With no currently active commands, press the TEST button and check the following:
DISPLAY
POSSIBLE CAUSE
ACTION BY SOFTWARE
PHYSICAL CORRECTIVE
ACTION
6E
(00 Sb)
The release handle is open.
-
Close the release handle and turn the
key to the close position.
Check that the release contact is
connected correctly.
The safety STOP contact is open.
-
Install a STOP button (NC) or jump-
er the ST contact with the COM
contact.
Sensing edge COS1 not connected
or incorrectly connected.
Set the parameter
if not used
or to disable
Jumper contact COS1 with contact
COM, if not used or to disable
Sensing edge COS2 not connected
or incorrectly connected.
Set the parameter
if not used
or to disable
Jumper contact COS2 with contact
COM, if not used or to disable
Photocell FT1 not connected or in-
correctly connected.
Set the parameter
e
if
not used or to disable
Jumper contact FT1 with contact
COM, if not used or to disable.
Check connection referring to rela-
tive connection diagram.
Photocell FT2 not connected or in-
correctly connected.
Set the parameter
e
if
not used or to disable
Jumper contact FT2 with contact
COM, if not used or to disable.
Check connection referring to rela-
tive connection diagram.
)(
Both limit switches in open contact
state or not connected.
-
Check connection of limit switches.
)$
Gate is at gate closed limit switch. If the limit switch state indicated is
incorrect, check the setting of para-
meter
.
-
Gate open limit switch absent or not
connected.
-
Check connection of limit switches.
)&
Gate is at gate closed limit switch. If the limit switch state indicated is
incorrect, check the setting of para-
meter
.
-
Gate closed limit switch absent or
not connected.
-
Check connection of limit switches.
SS
If occurs with no voluntary com-
mand, the contact (N.O.) may be
faulty or one of the buttons may be
incorrectly connected.
-
Check PP - COM contacts and con-
nections to buttons.
&+
-
Check CH - COM contacts and con-
nections to buttons.
DS
-
Check AP - COM contacts and con-
nections to buttons.
SH
-
Check PED - COM contacts and con-
nections to buttons.
2U
If occurs with no voluntary com-
mand, the contact (N.O.) may be
faulty or the timer may be incorrectly
connected.
-
Check ORO - COM contacts. Contact
must not be jumpered if not used.
N.B:
press TEST to exit TEST mode.
We recommend troubleshooting safety device and input status errors with “corrective action by software” only.
Summary of Contents for B70/1DC
Page 4: ...4 FW r1 65 ...
Page 5: ...5 1 BH30 BM30 A A A A B A A B ...
Page 6: ...6 A B A 2 4 5 BH30 Scheda ricarica batteria B71 BC B71 BC battery charger ...
Page 8: ...8 4 BH30 CAVO MOTORE MOTOR CABLE ...
Page 20: ...20 17 PR1 PR2 L1 L2 PR1 PR2 Canali radio Radio channels ...
Page 21: ...21 n e ro b la c k gr igi o g rey 18 BH30 ...