66
5. Press and release
QUICKMENU
to select Master Channels. The following
screen is displayed:
M I D I S e t t i n g s
M u l t i t r a c k O F F
M a s t e r C h a n n e l
P D
S e n d / R e c v
6. To change the Master Channel in the display, use the Select knob to highlight
the Master Channel field (
PD
in the example above) then rotate the Alpha dial
to change the selection.
7. To change the Master Channel status in the display, use the Select knob to
highlight the Master Channel field (
Send/Recv
in the example above) then
rotate the Alpha dial to change the selection.
8. Press General Cancel (‘
0
’) to exit.
Registrations
In addition to note and volume information sent on the Master Channels, the Rodgers T787
sends and receives MIDI information related to registrations. This information can be used
to control the stops and couplers of a separate Rodgers organ or, more commonly, can be
recorded by a sequencer (along with the note and volume information on the Master
Channels) and then recreated during playback.
Registration information is normally transmitted and received in the form of System
Exclusive (SysEx) messages. Every time there is a change in a stop or coupler, a SysEx
message is generated by the organ which gives the updated status of
all
stops and couplers.
Each of these SysEx messages, then, communicates the status of the entire instrument.
If desired, the T787 can transmit Program Changes when combination pistons are pressed on
the organ. These messages only communicate which pistons are pressed, not the status of
stops and couplers. This is often useful when controlling the T787 from a remote MIDI
keyboard which sends Program Changes or from a different model of Rodgers organ. The
Program Changes are sent and received on one of the Master Channels.
System Exclusive messages normally provide the optimum control over registrations, both
those made by pressing pistons and those changed by hand. Factory default settings of both
Send and Receive are set to
Stops
(System Exclusive messages). Available options are:
Stops
,
Pistons
(Program Change messages),
Stops and Pistons
and
Off
.
All Master Channels are reset to
Send & Receive
when the organ is powered off.
!
Summary of Contents for Trillium T787
Page 1: ...Rodgers T787 Owner s Manual Copyright Rodgers Instruments LLC...
Page 2: ......
Page 6: ...iv...
Page 12: ...1...
Page 14: ...3...
Page 90: ...79 RODGERS T787 CONSOLE DIMENSIONS...
Page 92: ...81...
Page 96: ...85...
Page 100: ...89 INSTRUMENTS LLC 1300 N E 25th AVENUE HILLSBORO OREGON 97124 503 648 4181 1905 787B...