24
C r e s c e n d o S e t
C r e s c e n d o S e t
S T A G E :
M o d e S T D
1
The stops and couplers currently set on stage one of the 63 stages in the
Crescendo sequence turn on.
3. The current sequence may be viewed by advancing through the stages one at a
time using the Alpha Dial. At each stage, the stage number (1 to 63) is indicated
in the Console Display, and the stops and couplers set at this stage turn on.
4. To add one or more stops to the sequence, go to the stage where the stop(s) is to
be added, turn the stop(s) on, and press SET.
5. To delete a stop(s), go to the first stage in which the stop(s) turns on, turn the
stop(s) off, and press SET.
Each stop can be turned on at any stage and turned off at any later stage. As an example, assume
the SWELL 8' BOURDON is to turn on at stage 1 and off at stage 25. Go to stage 1, turn on the
SWELL 8' BOURDON, and press SET. Then go to stage 25, turn off the SWELL 8'
BOURDON, and press SET.
To clear the entire Crescendo sequence (stages 1 through 63), hold SET and press General
Cancel (0). This also resets the current stage number to 1 so that a new sequence can be entered.
When building a completely new sequence, it is advisable to first write the new sequence down,
then assign stage numbers from 1 to 63 to each stop or group of stops in the sequence.
Sometimes there are more stages than stops in the sequence, so it is necessary to skip some
stages to make the sequence end at or near stage 63. If this is not done, the sequence ends before
the Crescendo shoe is fully depressed.
To exit the CRESC SET MODE menu at any time, press General Cancel. Any changes in the
sequence made up to this point are saved.
Note: If the original factory setting is desired, see Restoring Factory Crescendo Setting below.
Locking Crescendo
1. Press and hold the
GT/PED UNENCL
piston for approximately five seconds
until CRESCENDO UNLOCKED appears in the Console Display.
2. While continuing to hold
GT/PED UNENCL
, rotate the Alpha Dial either
direction until the Console Display reads CRESCENDO LOCKED.
3. Release
GT/PED UNENCL
. The Crescendo is locked.
Summary of Contents for Trillium T787
Page 1: ...Rodgers T787 Owner s Manual Copyright Rodgers Instruments LLC...
Page 2: ......
Page 6: ...iv...
Page 12: ...1...
Page 14: ...3...
Page 90: ...79 RODGERS T787 CONSOLE DIMENSIONS...
Page 92: ...81...
Page 96: ...85...
Page 100: ...89 INSTRUMENTS LLC 1300 N E 25th AVENUE HILLSBORO OREGON 97124 503 648 4181 1905 787B...