Supplemental Drive Information
A-3
Control
(continued)
Frequency Control - Speed Regulation
with Slip Compensation (V/Hz Mode)
0.5% of base speed across 40:1 speed range
40:1 operating range
10 rad/sec bandwidth
with Slip Compensation (Sensorless Vector Mode)
0.5% of base speed across 80:1 speed range
80:1 operating range
20 rad/sec bandwidth
with feedback (Sensorless Vector Mode)
0.1% of base speed across 80:1 speed range
80:1 operating range
20 rad/sec bandwidth
Speed Control - Speed Regulation
without feedback (Vector Control Mode)
0.1% of base speed across 120:1 speed range
120:1 operating range
30 rad/sec bandwidth
with feedback (Vector Control Mode)
0.001% of base speed across 120:1 speed range
1000:1 operating range
125 rad/sec bandwidth
Torque Regulation
without fe/-10%
with fe/-5%
Selectable Motor Control:
Sensorless Vector with full tuning. Standard V/Hz with
full custom capability and vector control.
Stop Modes:
Multiple programmable stop modes including - Ramp,
Coast, DC-Brake, Ramp-to-Hold and S-curve.
Accel/Decel:
Two independently programmable accel & decel times.
Each time may be programmed from 0-3600 seconds
in 0.1 sec. increments
Intermittent Overload:
110% Overload capability for up to 1 minute
150% Overload capability for up to 3 seconds
Current Limit Capability:
Proactive Current Limit programmable from 20 to
160% of rated output current. Independently
programmable proportional and integral gain.
Electronic Motor Overload Protection:
Class 10 protection with speed sensitive response.
Investigated by U.L. to comply with N.E.C. Article 430.
U.L. File E59272, volume 12.
Encoder
Type:
Incremental, dual channel
Supply:
5V/12V Config/-5%
Quadrature:
90° +/-27° at 25° C.
Duty Cycle:
50% +10%
Requirements
Encoders must be line driver type, quadrature (dual
channel) or pulse (single channel), single-ended or
differential and capable of supplying a minimum of 10
mA per channel. The Encoder Interface Board
accepts 5V or 12V DC square-wave with a minimum
high state voltage of 3.5V DC (5V mode) and 7.0V DC
(12V mode). Maximum low state voltage is 1V DC (for
both 5V and 12V modes). Maximum input frequency is
250 kHz.
(1)
Applied noise impulses may be counted in addition to the standard pulse train causing erroneously high [Pulse
Freq] readings.
Category
Specification
E C
E C
E C
E C
E C
Summary of Contents for PowerFlex 70