Chapter
2
Installing the WIM
Chapter 2 provides instructions for installing and removing the WIM.
The WIM is offered in two styles: a NEMA 1 module (22-WIM-N1) and
a NEMA 4 module (22-WIM-N4S). Each style is installed differently.
The NEMA 1 WIM (22-WIM-N1) is installed in a HIM bezel
(22-HIM-B1) that is mounted in a remote location.
1.
If the HIM bezel is not mounted, refer to the
HIM Bezel Installation
Instructions
Publication No. 22HIM-IN002… for mounting details.
2.
Route the bezel cable to the drive. Connect the bezel cable to the DSI
port on the bottom of the drive.
3.
Install the WIM into the HIM bezel cradle (
Figure 2.1
).
Figure 2.1 Installing the WIM in a HIM Bezel
Topic
Page
Installing the NEMA 1 WIM (22-WIM-N1)
2-1
Installing the NEMA 4 WIM (22-WIM-N4S)
2-2
Removing the NEMA 1 WIM (22-WIM-N1)
2-4
Installing the NEMA 1 WIM (22-WIM-N1)
22-WIM-N1
(Wireless Interface Module)
22-HIM-B1
Bezel
PowerFlex 4/40/400 Drive
with Installed HIM
2 m (6.6 ft.)
Bezel Cable
Contains FCC ID: SNT-2XWIMNX
IC: 5450A-2XWIMNX
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and
2) this device must accept any interference received,
including interference that may cause undesired operation
Summary of Contents for PowerFlex 22-WIM-N1
Page 1: ...User Manual DSI Wireless Interface Module 22 WIM N1 22 WIM N4S FRN 1 xxx...
Page 4: ...soc ii Summary of Changes...
Page 10: ...P 4 About This Manual Notes...
Page 52: ...4 6 Troubleshooting Notes...
Page 56: ...A 4 Specifications Notes...
Page 96: ...Index 4...
Page 97: ...Index 5...
Page 98: ...Index 6...
Page 99: ......