Rockwell Automation Publication 20P-TD001K-EN-P - January 2021
57
PowerFlex DC Drive and Field Controller Technical Data
Fuses for Non-Regenerative Frame C and D Drives
AC input line and/or leg fuses are internally mounted and provided with frames C and D drives. See Fuse Code FS4 in PowerFlex DC Drive
Frame C and D Fuse Information on page
. Also, see Frame C Non-Regenerative Drive - AC Input Line Fuse Location on page
AC Input Line Fuses - 230V AC Input Frame C
Frame Drive Current
Rating Code
DC
Amps
AC
Line
Amps
Qty
Bussmann
Mersen
SIBA
Square Body - Flush End Contact
C
521
521
426
3
17 switch 170H0069
6,9 URD 32 TTF 1000 + switch MS 3-V1-5 BS
20 671 32.1000 + switch 28 001 04
700
700
571
Leg Fuses - 230V AC Input Frame D Drives
Frame Drive Current
Rating Code
DC
Amps
AC
Line
Amps
Qty
Bussmann
Mersen
SIBA
Square Body - DIN 43653 Stud-Mount
D
875
875
715
6
17 switch 170H0069
Y switch MS 3V 1-5 UR
20 635 32.900 + switch 28 001 04
1K0
1050
858
17 switch 170H0069
Z switch MS 3V 1-5 UR
20 635 32.1000 + switch 28 001 04
AC Input Line Fuses - 460V AC Input Frame C
Frame Drive Current
Rating Code
DC
Amps
AC
Line
Amps
Qty
Bussmann
Mersen
SIBA
Square Body - Flush End Contact
C
495
495
404.4
3
17 switch 170H0069
6,9 URD 32 TTF 800 + switch MS 3-V1-5 BS
20 671 32.800 + switch 28 001 04
667
667
544.9
17 switch 170H0069
6,9 URD 32 TTF 1000 + switch MS 3-V1-5 BS
20 671 32.1000 + switch 28 001 04
Leg Fuses - 460V AC Input Frame D Drives
Frame Drive Current
Rating Code
DC
Amps
AC Line
Amps
Qty
Bussmann
Mersen
SIBA
Square Body - DIN 43653 Stud-Mount
D
830
830
678.1
6
17 switch 170H0069
X switch MS 3V 1-5 UR
20 635 32.800 + switch 28 001 04
996
996
813.7
17 switch 170H0069
Z switch MS 3V 1-5 UR
20 635 32.1000 + switch 28 001 04
1K1
1162
949.4
17 switch 170H0069
A switch MS 3V 1-5 UR
20 635 32.1100 + switch 28 001 04
1K3
1328
1085.0
17 switch 170H0069
B switch MS 3V 1-5 UR
20 635 32.1250 + switch 28 001 04
1K4
1494
1220.6
17 switch 170H0069
C switch MS 3V 1-5 UR
20 635 32.1400 + switch 28 001 04
AC Input Line Fuses - 575V AC Input Frame C Drives
Frame Drive Current
Rating Code
DC
Amps
AC Line
Amps Qty
Bussmann
Mersen
SIBA
Square Body - Flush End Contact
C
540
540
441
3
17 switch 170H0069
6,9 URD 32 TTF 1000 + switch MS 3V 1-5 BS
20 671 32.1000 + switch 28 001 04
675
675
551
Leg Fuses - 575V AC Input Frame D Drives
Frame Drive Current
Rating Code
DC
Amps
AC Line
Amps
Qty
Bussmann
Mersen
SIBA
Square Body - DIN 43653 Stud-Mount
D
810
810
661
6
17 switch 170H0069
X switch MS 3V 1-5 UR
20 635 32.800 + switch 28 001 04
1K0
1080
881
17 switch 170H0069
Z switch MS 3V 1-5 UR
20 635 32.1000 + switch 28 001 04
1K2
1215
991
17 switch 170H0069
A switch MS 3V 1-5 UR
20 635 32.1100 + switch 28 001 04
1K3
1350
1102
17 switch 170H0069
B switch MS 3V 1-5 UR
20 635 32.1250 + switch 28 001 04
1K6
1688
1377
12
17 switch 170H0069
X switch MS 3V 1-5 UR
20 635 32.800 + switch 28 001 04