Rockwell Automation Publication 20P-TD001K-EN-P - January 2021
47
PowerFlex DC Drive and Field Controller Technical Data
PowerFlex DC Drives DC Analog Tachometer Terminal Block
Analog Tachometer Terminal Block Location
PowerFlex DC Drives Resolver Feedback Module
The resolver feedback module (catalog number 20P-RES-A0), which provides a drive interface to a selection of compatible resolvers, must
be ordered and purchased separately from the drive. The resolver option module includes the PowerFlex DC Drive Resolver Feedback Module
Installation Instructions, publication
, which provides installation and wiring information. See ‘Resolver Type Selection’ in the
PowerFlex Digital DC Drive User Manual, publication
, for more information on compatible resolvers. The PowerFlex DC drive is not
CE Certified when the resolver feedback module is installed in the drive.
ATTENTION:
The drive can overspeed if DIP switch S4 is set incorrectly, or the tachometer is wired incorrectly. Failure to
do so could result in damage to, or destruction of, the equipment.
DC Analog Tachometer Terminal Designations
No.
Signal
Description
–
Negative input
–
A
(Not Used)
B
C
+
Positive input
Feedback polarity is determined during the startup routine.
22.7 / 45.4 / 90.7 / 181.6 / 302.9V
(1)
max voltage
8 mA max current
(1) Maximum voltage depends on the configuration of DIP switch S4. For information on jumper settings, see the PowerFlex® Digital DC Drive User Manual, publication
20P-UM001
.
Recommended Signal Wire Size for DC Analog Tachometer
Signal Type
Terminal Block
(Terminals)
Wire Type and Size
(1)
(1) See Cable and Wiring Recommendations in the PowerFlex Digital DC Drive User Manual, publication
20P-UM001
.
Tightening Torque
N•m (lb•in)
Flexible (mm
2
)
Multicore (mm
2
)
AWG
DC Analog Tach
M3 (+ and –)
0.140…1.500
0.140…1.500
26…16
0.4 (3.5)
A
B
C
+
-
Analog Tachometer terminal block