![Rockwell Automation Allen-Bradley LDAT Series Installation Instructions Manual Download Page 73](http://html1.mh-extra.com/html/rockwell-automation/allen-bradley-ldat-series/allen-bradley-ldat-series_installation-instructions-manual_1475648073.webp)
LDAT-Series Integrated Linear Thrusters
73
Rockwell Automation Publication LDAT-IN001B-EN-P - March 2020
Wiring Examples for a Linear Thruster to an Ultra3000 Drive
Grounding Techniques for Feedback Cable Shield
W
V
U
GND
AM+
AM-
BM+
BM-
IM+
IM-
+5VDC
ECOM
BLUE
WHT/BLUE
GREEN
WHT/GREEN
GRAY
WHT/GRAY
BLACK
WHT/BLACK
RED
WHT/RED
1
2
3
4
5
10
14
6
12
TS-
S1
–
TS+
ORANGE
WHT/ORANGE
11
S2
S3
COM
YELLOW
WHT/YELLOW
13
8
3
4
5
6
1
2
14
15
16
17
12
11
13
9
10
D
C
B
A
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
4
3
2
1
Green/Yellow
Blue
Black
Brown
Shield
W
V
U
Motor Power
(TB1) Connector
LDAT-Series Integrated Linear
Thruster with Incremental Encoder
LDAT-S
xxxxxx-x
B
Three-phase
Motor Power
Thermostat
2090-UXBB-DM15 Drive
Mounted
Connector
Ultra3000 Digital
Servo Drive
Cable Shield
Ground Clamp
Motor Feedback
(CN2) Connector
Motor
Feedback
2090-CPWM7DF-
xx
AA
xx
(standard)
or 2090-CPWM7DF-
xx
AF
x
(continuous-flex)
Motor Power Cable
Note 1, 4
2090-XXNFMF-S
xx
(standard)
or
2090-CFBM7DAF
xx
(continuous-flex)
(flying-lead) Feedback Cable
Note 2
Ultra3000 Digital
Servo Drive
Cable Shield
Ground Clamp
Motor Power
(TB1) Connector
Motor Feedback
(CN2) Connector
2090-CPWM7DF-
xx
AA
xx
(standard)
or 2090-CPWM7DF-
xx
AF
x
(continuous-flex)
Motor Power Cable
Note 1, 4
LDAT-Series Integrated Linear
Thruster with Incremental Encoder
LDAT-S
xxxxxx-x
B
2090-UXBB-DM15 Drive
Mounted
Connector
2090-XXNFMF-S
xx
(standard)
or
2090-CFBM7DAF
xx
(continuous-flex)
(flying-lead) Feedback Cable
Note 2
Three-phase
Motor Power
Motor
Feedback
Thermostat
Clamp
Expose shield secured under clamp.
Clamp Screw (2)
Turn clamp over to hold small cable
secure.
Cable Tie
Exposed shield secured under
clamp.
Use 2090-K2CK-D15M connector
with these drives:
Kinetix 2000
Kinetix 300 and linear thruster with
incremental encoder
Use LDAT-CONNKIT-ABS connector with the
Kinetix 300 drive and a linear thruster with an
absolute encoder.
Use 2090-K6CK-D15M connector
with the
Kinetix 6000 drive.
Use 2090-UXBB-DM15 connector
with Ultra3000 drives.
Use 2090-K2CK-D15M connector
with these drives:
Kinetix 2000
Kinetix 300 and linear thruster with
incremental encoder
Use LDAT-CONNKIT-ABS connector with the
Kinetix 300 drive and a linear thruster with an
absolute encoder.
Use 2090-K6CK-D15M connector
with the
Kinetix 6000 drive.
Clamp
Expose shield secured under clamp.
Clamp Screw (2)
Turn clamp over to hold small cable
secure.
Use 2090-UXBB-DM15 connector
with Ultra3000 drives.
Cable Tie