40
LDAT-Series Integrated Linear Thrusters
Rockwell Automation Publication LDAT-IN001B-EN-P - March 2020
Tune
The linear thruster is a direct drive actuator. Tuning the linear thruster establishes a stable axis.
Follow these steps to tune the linear thruster.
1.
Attach your application load to the linear thruster.
2.
From the Autotune category enter the following recommended tuning parameters.
3.
Click Start.
Fine Tune
Use the facilities in the Tune, Velocity, Position and Accelerations Loop categories to meet your
specific application requirements.
Home
The Kinetix 6500 drive does not support Home-to-Torque homing. Use this link to the Sample
Code Library to download the AOI file called CIP Home to Torque.
ATTENTION:
Before you tune your linear thruster read and understand
Repetitive High Energy Impacts
and
Preventing Reduced Dynamic Control Performance on page 38
Parameter
Entry/Selection
Application Type
Basic
Loop Response
Medium
Load Coupling
Compliant