12
Rockwell Automation Publication 442G-UM002A-EN-P - December 2016
Chapter 1
General Description
Auxiliary/Manual Release
The manual release lets you unlock the guard door in the event of unforeseen
or uncommon circumstances.
The system enters into a latching fault (fault code 2744) when the manual
release is actuated.
To clear the fault, open the guard and cycle the LockSequenceFaultUnlatch
To unlock the guard door using the manual release:
1. Undo locking screw.
2. Use a screwdriver to lift the locking arm actuate the guard door handle.
Figure 6 - Auxiliary/Manual Release
IMPORTANT
The manual release is not a safety function. The machine manufacturer must
select and use a suitable release according to the risk assessment. The
correct function must be checked at regular intervals.
IMPORTANT
IMPORTANT
The system might not enter into a latching fault if the manual release is
actuated slowly.
ATTENTION:
The locking screw must be screwed back in and sealed after
assembly and after use of the manual release. Tightening torque is 0.5 N•m
(4.42 lb•in).
Torx (T8)