Rockwell Automation Publication 2198-RM004C-EN-P - March 2022
Chapter 2 Replacement Considerations
and
list power specifications and requirements for the
Kinetix 5100 drives.
Continuous output current (0-pk)
2.8 A
5.7 A
2.8 A
5.7 A
11.3 A
Peak output current (rms)
6.0 A
12.0 A
6.0 A
12.0 A
24.0 A
Peak output current (0-pk)
8.5 A
17.0 A
8.5 A
17.0 A
39.9 A
Continuous power output @ 240V nom or
120V (Voltage-doubler mode)
0.40 kW
0.80 kW
0.40 kW
0.80 kW
1.70 kW
Shunt On
390V DC
Shunt Off
375V DC
Overvoltage
430V DC
Short-circuit current rating
100,000 A (rms) symmetrical
Table 10 - Kinetix 300 Drives (Single-phase) Power Specifications (Continued)
Attribute
2097-V31PR0
2097-V31PR2
2097-V32PR0
2097-V32PR2
2097-V32PR4
Table 11 - Kinetix 300 Drives (single-phase and three-phase) Power Specifications
Attribute
2097-V33PR1
2097-V33PR3
2097-V33PR5
2097-V33PR6
AC input voltage
80…132V rms single-phase (120V nom)
80…264V rms single-phase (240V nom)
80…264V rms three-phase (240V nom)
AC input frequency
48…62 Hz
Main AC input current
Rms (nom) 120V input (voltage doubler)
Inrush (0-pk) max 120V input
Rms (nom) 120/240V input
Inrush (0-pk) max 240V input
5.0 A
68.0 A
3.0 A
136 A
8.6 A
1.15 A
5.0 A
2.3 A
15.0 A
1.15 A
8.7 A
2.3 A
24.0 A
5.65 A
13.9 A
11.3 A
Integrated AC line filter
No
No
No
No
Continuous output current (rms)
2.0 A
4.0 A
8.0 A
12.0 A
Continuous output current (0-pk)
2.8 A
5.7 A
11.3 A
17.0 A
Peak output current (rms)
6.0 A
12.0 A
24.0 A
36.0 A
Peak output current (0-pk)
8.5 A
17.0 A
39.9 A
50.9 A
Continuous power output @ 240V nom or
120V (Voltage-doubler mode)
0.50 kW
1.00 kW
2.00 kW
3.00 kW
Shunt On
390V DC
Shunt Off
375V DC
Overvoltage threshold
430V DC
Short-circuit current rating
100,000 A (rms) symmetrical
Table 12 - Kinetix 300 Drives Control Power Specification
Attribute
Kinetix 300 Drives
Control power input voltage
20…26V DC
Control power input current
Nom
Inrush max (0-pk)
500 mA
30 A