Safety Guidelines
Electrical Hazards
50
MagneMotion
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
Electrical Hazards
At maximum load, the QuickStick High Thrust motors and QSMC motor controllers are capa-
ble of drawing 400V DC at 15 Amps. At maximum load, the QuickStick High Thrust motors
and QuickStick HT 5700 Inverters are capable of drawing 458–747V DC at 13.7 A.
The QuickStick HT motor controllers, power supplies, node controllers, network switches,
and power modules are connected to the AC Mains of the facility and can generate hazardous
energy. The proper precautions for operating and servicing electrical equipment must be
observed. These precautions include following facility lockout/tagout procedures, and any
other specified action within the facility where the QSHT components are being used.
SHOCK HAZARD:
To avoid electric shock, all electrical
power to the QuickStick HT transport system must be dis-
connected per the facility lockout/tagout procedure before
servicing to help prevent the risk of electrical shock.
SHOCK HAZARD:
To avoid electric shock, do not open
any QuickStick HT component. Motors, controllers, and
other components do not contain any user-serviceable parts.
Do not turn on power to the power supplies, motor control-
lers, and node controllers until after connecting all other
transport system components.
NOTICE
To avoid equipment damage:
•
Make sure that the transport system is properly grounded.
•
Make sure that all vehicles are grounded to the guideway
through conductive wheels or static brushes.
•
Do not connect or disconnect any components while the
transport system has power, QuickStick HT motors are
not hot-pluggable.