Specifications and Site Requirements
Site Requirements
QuickStick HT User Manual
173
Rockwell Automation Publication MMI-UM007F-EN-P - September 2020
Site Requirements
Environment
Motors
Temperature:
Operating: 0° C to 50° C [32° F to 122° F]
Storage: -18° C to 50° C [0° F to 122° F]
Humidity:
85% Maximum (relative, noncondensing)
QSMC Motor Controllers
Temperature:
Operating: 0° C to 50° C [32° F to 122° F]
Storage: -18° C to 50° C [0° F to 122° F]
Humidity:
85% Maximum (relative, noncondensing)
QSHT 5700 Inverters
Temperature:
Operating: 0° C to 50° C [32° F to 122° F]
Storage: -18° C to 50° C [0° F to 122° F]
Humidity:
5–95% Maximum (relative, noncondensing)
Magnet Arrays
Temperature:
Operating: 0° C to 50° C [32° F to 122° F]
Storage: -18° C to 60° C [0° F to 140° F]
Humidity:
85% Maximum (relative, noncondensing)
Derating at High Altitude
When operating in a high altitude environment with lower air pressure, the operating tempera-
ture range must be derated compared to that of sea level.