32
Industrial 18.1" Flat Panel Monitor
Publication 6185-UM001B-EN-P
Connecting DC Power (DC Power Option)
All models of the 6185 Flat Panel Monitor can be run with direct current.
Table C below lists the power requirements for each model.
Table C
DC Power Requirements for Model 6185 18" Flat Panel Monitors
Model
Power Requirement
Panel mount (6185-D)
Rack mount (6185-N)
24 VDC (18-32 VDC)
Versa mount (6185-V)
12 VDC (±5%)
Note:
The Versa mount unit can be directly connected to a power
source using a cable with a locking DIN connector provided
with your equipment.
To connect DC power to the panel mount (6185-D) or rack mount (6185-N)
monitor:
1.
Turn off the main switch or breaker.
2.
Use the ground terminal on the monitor below the power connector
to establish a chassis-to-earth ground connection. Secure one end of
a ground strap to the ground terminal. Connect the other end of the
ground strap to a good earth ground.
The ground terminal is an M5 screw.
ATTENTION:
Chassis ground must be connected for
safe operation of the monitor. The DC screw terminals on
the monitor have a chassis ground pin. However, some
DC sources may not provide a proper ground path. If you
fail to ground the monitor properly, the setup may result
in personal injury from electrical shock or damage to the
equipment.
ATTENTION:
EXPLOSION HAZARD! – Do not
disconnect equipment unless power has been switched off
or the area is known to be non-hazardous.