Appendix F MicroLogix 1400 Distributed Network Protocol
222
Read Only
INT
1
1
Support for binary output events
0
223
Read Only
UINT
4
2
Max binary output index
256*16
224
Read Only
UINT
4
2
Number of binary outputs
0…256*16
225
Read Only
INT
1
1
Support for frozen counter events 1
226
Read Only
INT
1
1
Support for frozen counters
1
227
Read Only
INT
1
1
Support for counter events
1
228
Read Only
UINT
4
2
Max counter index
256*2
229
Read Only
UINT
4
2
Number of counter points
0…256*2
230
Read Only
INT
1
1
Support for frozen analog inputs
0
231
Read Only
INT
1
1
Support for analog input events
1
232
Read Only
UINT
4
2
Maximum analog input index
256*3
233
Read Only
UINT
4
2
Number of analog input points
0…256*3
234
Read Only
INT
1
1
Support for double-bit binary input
events
1
235
Read Only
UINT
4
2
Maximum double-bit binary input
index
256*8
236
Read Only
UINT
4
2
Number of double-bit binary input
points
0…256*8
237
Read Only
INT
1
1
Support for binary input events
1
238
Read Only
UINT
4
2
Max binary input index
256*16
239
Read Only
UINT
4
2
Number of binary input points
0…256*16
240
Read Only
UINT
4
2
Max transmit fragment size
2048 (27…2048). When this value is written to the
controller, the communication configuration file is
changed to this value.
241
Read Only
UINT
4
2
Max receive fragment size
2048
242
Read Only
VSTR
length of the
string value
length of the
string value
Device manufacturer's software
version
This variation returns firmware FRN. FRN 1.00.
Supported ranges: FRN x.yy, FRN x.yyy, FRN xx.yy or
FRN xx.yyy where x, xx is 0 ~ 99 and yy, yyy 00 ~ 999.
For example, FRN 1.00, FRN 1.05, FRN 12.05, FRN 102.27
or FRN 103.117.
243
Read Only
VSTR
length of the
string value
length of the
string value
Device manufacturer's hardware
version
This variation returns
hardware series and
revision of the controller.
HW SER A/REV 01.
This variation returns
hardware series and
revision of the controller.
HW SER A/REV 03.
Supported ranges: HW SER x/REV yy where x is A ~ F
and yy is 00 ~ 31.
For example, HW SER A/REV 01, HW SER B/REV 03, or
HW SER C/REV 31.
244
-
-
-
-
Reserved for future assignment
-
-
245
Read /Write
VSTR
length of the
string value, max
255 bytes
length of the
string value, max
255 bytes
User-assigned location name
"". Non-NULL terminated.
246
Read /Write
VSTR
length of the
string value, max
255 bytes
length of the
string value, max
255 bytes
User-assigned ID code/number
"". Non-NULL terminated.
247
Read /Write
VSTR
length of the
string value, max
255 bytes
length of the
string value, max
255 bytes
User-assigned device name
"". Non-NULL terminated.
248
Read Only
VSTR
12
12
Device serial number
This variation returns Ethernet MAC ID. 0000BCxxxxxx.
249
Read Only
VSTR
6
6
DNP subset and conformance
This variation returns
Subset level and Test
procedure version.
2:2008.
This variation returns
Subset level and Test
procedure version.
2:2009.
Object Group 0, Variations for Attribute Set 0 (Continued)
Variation
Read /Write Attribute
Data Type
Length in Bytes
(Series A)
Max Length in
Bytes (Series B
and Series C)
Description
Value (Series A)
Value (Series B)