Chapter 1 Hardware Overview
•
1763-NC01 Series A or later
•
1747-CP3 Series A or later
Programming
Programming the MicroLogix 1400 controller is done using RSLogix 500/
RSLogix Micro software, version 8.10.00 or later for Series A controllers and
version 8.30.00 or later for Series B and Series C controllers. Communication
cables for programming are available separately from the controller and
software.
Firmware Revision History
Features are added to the controllers through firmware upgrades. Use the
listing in
to be sure that your controller’s firmware is at the level you
need. Firmware upgrades are not required, except to allow you access to the
new features.
ATTENTION: UNSUPPORTED CONNECTION
Do not connect a MicroLogix 1400 controller to another MicroLogix family
controller such as MicroLogix 1000, MicroLogix 1200, MicroLogix 1500, or
the network port of a 1747-DPS1 Port Splitter using a 1761-CBL-AM00 (8-
pin mini-DIN to 8-pin mini-DIN) cable or equivalent.
This type of connection will cause damage to the RS-232/RS-485
communication port (Channel 0) of the MicroLogix 1400 and/or the
controller itself. The communication pins used for RS-485
communications on the MicroLogix 1400 are alternately used for 24V
power on the other MicroLogix controllers and the network port of the
1747-DPS1 Port Splitter.
Table 1 - MicroLogix 1400
Catalog Number
OS
(1)
Series
Letter
OS Revision
Letter
OS
Firmware
Release No.
Release Date
Enhancement
1766-L32AWA
1766-L32BWA
1766-L32BBB
A
A
FRN1
August 2005
Initial product release.
A
B
FRN2
October 2005
According to the SRAM component, MicroLogix 1400 may cause Hard-fault at the
start of the Operating System in the very high temperature environment. Corrected.
A
C
FRN3
February 2006
Added Data file write feature through web server.
1766-L32AWA
1766-L32BWA
1766-L32BBB
B
A
FRN4
February 2007
• Direct connection to RS-485 Network for DF1 half-duplex Master driver.
• Direct connection to RS-485 Network for DF1 half-duplex Slave driver.
• Direct connection to RS-485 Network for ASCII driver.
• Selectable Stop/Data Bits for Modbus Master RTU driver.
• Selectable Stop/Data Bits for Modbus Slave RTU driver.
• Selectable Stop/Data Bits for ASCII driver.
• Settable Inactivity Timeout feature for Ethernet driver.
• Unsolicited Ethernet messaging to RSLinx® OPC topic.
• CIP™ Generic messaging through the Ethernet port.
• Unconnected EtherNet/IP protocol for Ethernet driver.
• IP conflict detection mechanism.
• E-mail feature.
• Ethernet MSG break bit.
• DNS functionality when E-mail feature is used.
• Change IP Address using Ethernet MSG instruction.
• ST file type for all PCCC commands.
• HSC (High-Speed Counter) up to 40 K Hz.
• PTO/PWM up to 40 K Hz.
• 2-channel Analog Input Filter.
• Web View Disable for Data Files.
1766-L32AWA
1766-L32BWA
1766-L32BBB
B
B
FRN5
May 2007
• Fixed defect for CIP Messaging Error when CIP service code is 4Bh or 4Ch.
• Fixed defect for the EtherNet/IP List Identity reply.
• Fixed defect for window size error in TCP/IP stack.
• Improved system interrupt delay time.