![Rocal G 45 LD -LI Assembly And Operating Manual Download Page 13](http://html1.mh-extra.com/html/rocal/g-45-ld-li/g-45-ld-li_assembly-and-operating-manual_1472113013.webp)
Página
13
de
24
ENGLISH
A:
DETAILED COMPONENTS
1. Mono-block fireplace with guillotine opening
2. Indoor Heat-resistant panels
3. Grill
4. Handle to manage grill and ash box
5. Ash box
6. 6 air outlet adaptors
7. Exothermic glove and anti-scratching cloth for cleaning the plate
8. Deflexed panel
9. Pot with aerosol painting for final finish
10. Bag with 4 screws to level the apparatus
11. Tool to manage registers, grill and ash box
12. Envelope containing user’s guide: characteristics, assembly, operating and guarantee
13. 2 pieces framework for panel support
14. Rectangular piece that control the load
B:
DIAGRAMS AND SIZES
C:
ASSEMBLY PICTURES
D:
TECHNICAL CHARACTERISTICS
Parameter
Value
Maximum smokestack intake
11-13 Pa
Fire type
On and Off
Fuel consumption
4 Kg/h
Mass smoke intake
16,09 g/s
Nominal efficiency
71%
Output
13,5 Kw
Maximum output
19 Kw
Average temperature of fumes directly into the smoke outlet
403ºC
CO concentration at an average of 13% O2
0,39%
Fuel load (test)
3 Kg
Period time to test
45 min
Average smokestack intake (test)
11,7 Pa
Net Weight
295 Kg
Maximum fuel load
5 Kg
1. INSTALLATION PROCEDURES
ALL LOCAL REGULATIONS, INCLUDING THE ONES ACCORDING TO THE NATIONAL OR
EUROPEAN NORMS MUST BE ACCOMPLISHED WHEN PROCEEDING TO INSTALL THE
FIREPLACE.
1.1. Mono-block fire. It is a fireplace with stainless steel panels which has a deflexed panel,
rectangular piece that control the load, dissembled smoke connection and framework piece with
four sides, evolving convector outdoor chamber and six smoke outlets at the top part.
1.2. Freight
(1-2)
. In order to facilitate its mobility and installation, two rings on the upper part
have been provided in case of crane-pick up transportation.
1.3. Blockage off and door check
(3).
Remove door screws. Once the blockage is off, check
mechanism of guillotine opening so it works properly. In some occasions, due to freight, some
failures can be caused: collocation, incorrect level, dilatations, counterweight onto the door so it
gets unlevelled etc. To balance it again, remove front framework, and add or subtract weight (3
mm plates). Once the door is rebalanced, put the panel back and the door will work properly.
1.4. Floor. This fireplace must be assembled on floors which provide an adequate bearing
capacity. If the resistance is not enough, a panel of balance would be required to distribute the
whole weight of the fireplace.