Robustel GoRugged M1000 Pro User Guide
RT_M1000 Pro_UG_v01.01
27.12.2011
48 / 59
Confidential
Chapter 5.
Appendix
5.1
Factory Settings
Factory setting of the gateway COM port under
Config Mode and Normal Mode
is:
Data bits = 8
Parity = none
Stop bits = 1
Baud = 115200 bps
Flow control = none
5.2
Restore to Factory Default
The gateway could be restored to factory default by Modem Configurator Pro, SMS or hardware operation.
Following steps indicate how to restore to factory default by hardware operation:
1.
Set the gateway under Normal Mode, power on the gateway;
2.
Within 3 seconds, change the gateway from Normal Mode to Config Mode;
3.
Within 3 seconds, change the gateway from Config Mode to Normal Mode again;
4.
Within 3 seconds, change the gateway from Normal Mode to Config Mode again;
5.
Restore successfully.
Note
: PIN setting, Phone Book settings and COM settings will not be restored to factory default.
5.3
SMS Commands for Remote Control
M1000 Pro supports remote configuration and remote gateway status reading via SMS.
An SMS command has following structure:
Password:cmd1,a,b,c;cmd2,d,e,f;cmd3,g,h,i;...;cmdn,j,k,n
Note
:
1.
Password: SMS control password is configured at
Basic->SMS Control->Password
, which is an optional
parameter.
When there is no password, SMS command has following structure:
cmd1;cmd2;cmd3;…;cmdn
When there is a password, SMS command has following structure:
Password:cmd1;cmd2;cmd3;…;cmdn
2.
Cmd1, cmd2, cmd3 to Cmdn, which are command identification number 0000 – 9999
3.
A, b, c to n, which are command parameters
4.
The semicolon character (‘;’) is used to separate more than one commands packed in a single SMS.
5.
After setting new parameters for M1000 Pro, please use 0004 command to save parameters and reset the
gateway, then the new parameters will take effect.