This tab describes Digital Output settings.
Networks
Item
Description
Default
Alarm Source
Digital Output acts according to different alarm source.
Selected from DI Alarm, SMS Control, Call Control, selection can be
one or more.
DI Alarm: Digital Output triggers the related action when there is
alarm from Digital Input.
SMS Control: Digital Output triggers the related action when
receiving SMS from the number in the phone book.
Call Control: Digital Output triggers the related action when receiving
phone call from the number in the phone book.
Null
Alarm On Action
Digital Output acts when there is an alarm.
Selected from OFF, ON, Pulse, Null.
OFF: Open when triggered.
ON: Short contact when triggered.
Pulse: Generates a square wave as specified in the pulse mode
parameters when triggered.
Null: Do nothing.
Null
Alarm Off Action
Digital Output acts when alarm recovered.
Selected from OFF, ON, Pulse, Null.
OFF: Open when triggered.
ON: Short contact when triggered.
Pulse: Generates a square wave as specified in the pulse mode
parameters when triggered.
Null: Do nothing.
Null
Status When Power
On
Specify the Digital Output status when power on.
Selected from OFF, ON.
OFF: Open.
ON: Short contact.
Null
Keep On
Available when digital output Alarm On Action/Alarm Off Action
status is ON, input the Digital Output keep on status time.
Input from 0 to 255 seconds. (0=keep on until the next action)
0
Triggering Alarm
Available when enable SMS Control in Alarm Source.
Input the SMS content to enable “Alarm On Action” by SMS. (70 ASIC
II char max)
Null
Recovering Alarm
Available when enable SMS Control in Alarm Source.
Input the SMS content to enable “Alarm Off Action” by SMS. (70 ASIC
II char max)
Null
Phone Group
The alarm SMS will send to specified phone group.
Each phone group include up to 10 phone numbers.
Null
Low
Available when enable Pulse in Alarm On Action/Alarm Off Action.
In Pulse Output mode, the selected digital output channel will
1