6.
E.g., 1234:1001,M1000 Pro;0004
In this command, password is 1234, and we set device name as “M1000 Pro”, then save parameters and reset the
gateway to take effect with command 0004.
Cmd
Description
Syntax
Comments
Control Commands
0000
Set Factory Defaults
password:cmd or cmd
if no password, please use
command "cmd", or use
command "password:cmd" if
there is a password.
Following commands are the
same.
0001
Reset Device
cmd
0002
Save Parameters
cmd
0003
Get Device Status
cmd
0004
Save Parameters and Reset
Device
cmd
0005
Clear Event Count
cmd
0006
Start Event Counter
cmd
Set Commands
1000
Set Comm Parameters
cmd,baud
rate,parity,data
bits,stop
bits,flag
baud rate: 1200 - 115200
parity: n,o,e,m,s
data bits: 7,8
stop bits: 1,2
*flag: (can be null)
0 - RS232
1 - RS485
1001
Set Device Name
cmd,name
name(max 20 bytes)
1002
Set Init. String
cmd,string
string(max 40 bytes)
1003
Set SIM Card Pin
cmd,flag1,pin,flag2,newPin
flag1:
0 - disable pin lock
1 - enable pin lock
pin(4 - 8 bytes)
flag2:
0 - disable change pin
1 - enable change pin
*newPin(4 - 8 bytes and can be
null)
1004
Set SMS Control Passwd
cmd,passwd
*passwd(max 20 bytes and can be
null)
1005
Set APN
cmd,apn
apn(max 20 bytes)
1006
Set User Name
cmd,user name
user name(max 20 bytes)
1007
Set Passwd
cmd,passwd
passwd(max 20 bytes)
1008
Set Dns
cmd,mode,dns1,dns2
mode: