FT 300 Force Torque Sensor - Instruction Manual
31
l
Tap the plus button (+) to add the Sensor’s URCaps package.
l
Open Robotiq_Force_Torque_Sensor-X.X.X.urcap.
l
Restart PolyScope to complete the URCap installation.By doing so,
you accept the License Agreement that is detailed inthe URCap Inform-
ation text box (see below for the License Agreement).
l
When PolyScope reopens, the ActiveDrive toolbar will appear on
the screen.
If the Force Torque Sensor is mounted on the robot for the first time, the calibration must be performed. Refer to the Calibration
Procedure with Universal Robots section for the calibration procedure.
Warning
The sensor must be recalibrated after each uninstall / install on the robot. Mounting screws will induce internal stress that
needs to be compensated for. Not doing so will significantly affect the sensor signal.