The actual formula is as follows:
Distance = (Destination - Counter value) / Divider
Where: divider is a configurable parameter of value 1, 2, 4, 8, 16, 32, 64 or 127
If computed distance is less than -127, then reported distance is -127
If computed distance is larger than +127, then reported distance is +127
Important Notice
Encoders do not report an absolute position value but a count that is relative to the
point where the motor shaft was at power up. It is typically necessary to have the
motors moved to a “home” position and reset the counters at that reference point.
RS232 Communication with the Encoder Module
The contains its own Microcontroller and firmware in Flash. When present, it responds to a
large set of dedicated commands and queries via the controller’s serial port. See “RS232
Encoder Command Set” on page 145.
Destination= 50,050
distance at
divider
50
1
25
2
12
4
6
8
3
16
1
32
0
64
0
128
Counter= 50,000
FIGURE 46. Small distance computation example
Destination= 50,000
distance at
divider
127
1
127
2
127
4
127
8
127
16
127
32
78
64
39
128
Counter= 45,000
FIGURE 47. Large distance computation example
Summary of Contents for Dual Channel Digital Motor Controller AX2550
Page 2: ...2 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 4: ...4 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 12: ...12 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 14: ...Important Safety Warnings 14 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 92: ...Closed Loop Position Mode 92 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 154: ...154 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 160: ...160 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 186: ...Mechanical Specifications 186 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...