Serial (RS-232) Controls and Operation
136
AX1500 Motor Controller User’s Manual
Version 1.9b. June 1, 2007
This parameters selects the various open loop and closed loop operating modes as well as
the feedback method.
Amps Limit
Address:
^02
Access:
Read/Write
Effective:
After Reset or ^FF
This parameter configures the controller’s Amps limit. Note that this limits the amps flow-
ing out of the power supply. Current flowing through the motors may be higher.
Bit
Definition
See pages
2:0
Motor Control Mode
0 = A & B separate speed open loop
(default)
1 = A & B mixed speed open loop
2 = A speed open loop, B position
3 = A & B position
4 = A & B separate speed closed loop
5 = A & B mixed speed closed loop
6 = A speed close loop, B position
page 40
page 93
page 81
6:3
Reserved
6
Ch1 Feedback type
0 = Analog
1 = Encoder
page 93
page 81
7
Ch2 Feedback type
0 = Analog
1 = Encoder
Bit
Definition
See pages
3:0
Coarse Amps
0 = 7.5A
1 = 11.25A
2 = 15A
3 = 18.75A
4 = 22.5A
5 = 26.25A (default)
6 = 30A
page 42
7:4
Fine Amps
Mutliply this number by 0.25 and sub-
stract result from the Coarse Amps value
Summary of Contents for Dual Channel Digital Motor Controller AX2550
Page 2: ...2 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 4: ...4 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 12: ...12 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 14: ...Important Safety Warnings 14 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 92: ...Closed Loop Position Mode 92 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 154: ...154 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 160: ...160 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 186: ...Mechanical Specifications 186 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...