AX1500 Motor Controller User’s Manual
139
Accessing & Changing Configuration Parameter in Flash
This parameter configures the transfer curve that is applied the input command.
Left/Right Adjust
Address:
^0B
Access:
Read/Write
Effective:
After Reset or ^FF
This parameter configures the compensation curve when motors are spinning in one direc-
tion vs. the other.
Default Encoder Time Base 1 and 2
Address:
^0B - Encoder 1
^0C - Encoder 2
Access:
Read/Write
Effective:
After Reset or ^FF
These parameters are the Encoder Time base values that are loaded after the controller is
reset or powered on. Time Bases are used to determine rotation speed depending on the
Encoder’s resolution. Time Bases can be changed at Runtime using separate commands
(see page 142). Time Base values are integer number from 0 to 63. These parameters are
only effective on controllers equipped with Encoder Modules.
Bit
Definition
See pages
7:0
(0) = Linear (no exponentiation - default)
1 = strong exponential
2 = normal exponential
3 = normal logarithmic
4 = strong logarithmic
page 109
Bit
Definition
See pages
7:0
0, 1, ..., 6 = -5.25%, -4.5%, ...,-0.75%
(7) = no adjustment (default)
8, ..., D, E** = +0.75, ..., +4.5%, +5.25%
page 47
Bit
Definition
See pages
7:0
0 to 63 (16) default
page 76
Summary of Contents for Dual Channel Digital Motor Controller AX2550
Page 2: ...2 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 4: ...4 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 12: ...12 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 14: ...Important Safety Warnings 14 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 92: ...Closed Loop Position Mode 92 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 154: ...154 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 160: ...160 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...
Page 186: ...Mechanical Specifications 186 AX1500 Motor Controller User s Manual Version 1 9b June 1 2007...