Specifications
3-3
Robostar Co., Ltd
3.5
How to Set Input/Output Data Size
The use of Rotary Switch allows you to set Data Size of communication with Master.
1)
Turn the power to N1 controller OFF.
2)
Set a mode using the Rotary Switch in Fig. 3.1 ①.
Mode Setup Value
Value
Mode
99
Input Data Size setup Mode
98
Output Data Size setup
Mode
Fig. 3.4 Input Data Size Setup Mode Table 3.4 Mode Setup Value
3)
Use the Rotary Switch in Fig.3.1 ② to set input/output Data Sizes.
Setup Values for Input/Output Data Size
Value
Data Size
0
8 byte
1
16 byte
2
32 byte
3
46 byte
Values other than the
above values
8 byte
Fig. 3.4 Input Data Size Setup Mode Table 3.4 Mode Setup Value
※
The Module supported from N1 controller only supports 8Ⅹ8 Byte and 46Ⅹ46 Byte.
4)
Turn power to N1 controller ON.
5)
Check if LED (Input/output setup LED) is blinking (performing ON->OFF 2~3times).
Fig. 3.6 Input/Output Setup LED
6)
Repeat the above process to set Data Size for input/output.
Input setup LED
Output setup LED